ADTRAN D4-U-RPM User Manual

Figure 1. adtran d4 u-rpm

Advertising
background image

SECTION 61100022L1-5

PAGE 1

FIGURE 1. ADTRAN D4 U-RPM

61100.022L1-5C

C A U T I O N

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

PRACTICES

®

WECO is a registered trademark of AT&T Technologies

Contents

Paragraph

Page

1.

General ............................................................ 1

Figure 1. ADTRAN D4 U-RPM ......................................... 1

2.

Installation ....................................................... 2

Figure 2. U-RPM Application ........................................... 2
Table A. U-RPM Option Selections ................................. 2

3.

Connections .................................................... 2

Figure 3. Connector Pin Assignments ........................... 3
Figure 4. U-RPM Option Locations ................................. 3

4.

Maintenance .................................................... 3

5.

Warranty And Customer Service .................. 3

MODEL U-RPM

D4-U-RPM

U-REPEATER POWERING MODULE

INSTALLATION/MAINTENANCE

1.0

GENERAL

1.01

This section provides installation and

maintenance

information for the ADTRAN U-Repeater

Powering Module (U-RPM), Part Number: 1100022L1.
Figure 1 shows the front of the unit. Figure 2 represents
a generic module application. Figure 3 shows the
connector pin assignments for the U-RPM. The unit's
part number and basic features are:

Section 61100022L1-5
Issue 3, April 1992
CLEI Code # DDRPG701_ _

Part

Equipment

Number

Features

U-Repeater

1100022L1

Repeater Powering for

Powering

ADTRAN ISDN mid-point loop

Module

repeater; Loop resistance fault

(U-RPM)

indicator; Class A2 or Class A3
operation.

1.02

This practice has been reissued to reflect the
addition of a field selectable powering option in

Paragraph 2.04 and Figure 4 and the latest CLEI
designation. Issue 3 adds a new Sales telephone number.

1.03

The U-RPM is a channel plug-in used in the
ADTRAN GPC-1 or AD4-24 Shelves or the

WECO

®

D4 channel bank, to provide sealing current

power for the ADTRAN ISDN mid-point loop repeater.

1.04

The U-RPM provides three functions for the
ADTRAN ISDN mid-point loop repeater. These

functions are:

1.

The D4-U-RPM receives -48 VDC power
from the facility power source and sends
constant 85 mA of sealing current down
the loop to power the U-Repeater.

2.

A passive customer data flow is allowed
through the D4-U-RPM.

3.

The D4-U-RPM monitors the line for
excessive resistance or open conditions.

Advertising