Tsunami Bilge Pump

4606, 4608, 4612, 4613 Series

Installation Instructions

SAVE THESE INSTRUCTIONS
Form Number 69390 Rev. A

10-03

3

®

WARNING

Read all instructions carefully before installing and using this product.
To prevent personal injury, disconnect the power source when installing
or servicing this product. Always remove the boat from the water before
using 120V AC power tools.

DO NOT use pump to remove gasoline, oil or other flammable liquids.
Always use the fuse amperage rating specified for your pump model.
Failure to do so could result in serious personal injury or fire hazards.

Attwood bilge pumps are designed to exhaust STANDING WATER
ONLY. They are not intended to prevent rapid accumulation of
on-board water due to rough weather, hull damage, and/or other
unsafe navigational conditions.

Refer to Specification Chart to be sure you have selected the
proper pump:

MATERIALS REQUIRED
• Three #8 stainless fasteners, suitable length for mounting surface
• Cordless drill and 1/8" (3mm) bit
• Hose clamps (Attwood # 9185, 2 per connection)
• Mounting pad: marine plywood, fiberglass cloth and resin

• Manual (# 7615A) or automatic float switch (#4201 or 4202)
• Fuel-resistant, reinforced smooth bore outlet hose

INSTALLATION LOCATION
1. Position pump in the lowest accessible part of the bilge. On

sailboats, location should be centered over keel. (Figure 1)

12-Volt Models

ABYC Specifications

ISO Specifications

@13.6 VDC

@12 VDC

(GPH = Gal. Per Hour)

(LPH = Liters Per Hour)

0 ft.

3.3 ft

6.7 ft

0kPa

10kPa

Max

Part

Outlet

Head

Head

Head

Head

Head

Head

Num./

Hose Motor Amp GPH/

GPH/

GPH/

LPH/

LPH/

([email protected]/

Series

I.D.

Cart.

Fuse amps

amps

amps

amps

amps

kPa@12v)

4606/600 3/4"

4620

2.5A 500/1.5

400/ 1.5 250/1.5 1705/1.3 1250/1.3 8'/27

4608/800 3/4"

4622

4A

800/3.0

660/3.0 510/3.0 2840/2.5 2274/2.5 14'/33

4612/1200 1-1/8" 4624

5A

1200/3.5 900/3.5 700/3.5 4169/3.0 3000/3.0 11' 7"/28

24-Volt Models

ABYC Specifications

ISO Specifications

@24.0 VDC

@24.0 VDC

(GPH = Gal. Per Hour)

(LPH = Liters Per Hour)

0 ft.

3.3 ft

6.7 ft

0kPa

10kPa

Max

Part

Head

Head

Head

Head

Head

Head

Num.

Amp GPH/

GPH/

GPH/

LPH/

LPH/

(ft.@24v/

Series

Fuse amps

amps

amps

amps

amps

kPa@24v)

4609/800 3/4"

4623

2A

800/1.3

660/1.3 500/1.3 2842/1.1 2160/1.1 14'/31

4613/1200 1-1/8" 4625

2A

1200/1.5 900/1.5 725/1.5 4100/1.3 3100/1.3 11'/28

2. Do not mount pump directly to hull. Attach base strainer to a

marine plywood mounting pad that is fiberglassed to the hull.

HOSE CONNECTION INSTRUCTIONS
IMPORTANT:
To prevent airlock, hose must rise continually upward
to the thru-hull connector with no dips or sharp bends. Support hose
if necessary.

1. Orient pump outlet for a direct, unobstructed hose path.

2. Secure all connections with hose clamps.
3. If no thru-hull connector exists, install at 12" min. (25mm) above

water line. Apply marine sealant around thru-hull flanges on
interior and exterior of hull.

PUMP MOUNTING INSTRUCTIONS
1. To access mounting holes, remove base strainer. Hold housing with

one hand, depress locking tab with other. Twist counter-clockwise
and remove pump housing from base. It is not necessary to remove
motor cartridge for installation. (Figure 2)

Figure 1

Thru-Hull Connector

Hose & Clamp

Hose MUST Rise

Upward with NO DIP

Suitable Mounting Pad

Base Strainer

12" min. Above

Water Line

2. Use base as template to mark 3 mounting holes in mounting pad.

CAUTION: Do not drill through hull. Before drilling be sure mounted
pump will be correctly positioned with pump nozzle pointing toward
thru-hull connector. (Figure 1)

3. Remove base. Drill three 1/8" (3mm) pilot holes at marked locations.
4. Replace base. Attach with #8 stainless steel fasteners.

5. Re-attach pump to base. Insert into base, twist clockwise until tab

snaps in and prevents turning. (Figure 2)

WIRING INSTRUCTIONS
Make all wire connections above the highest water level. Use marine
grade wire connectors only. Waterproof all connections with suitable
materials. (Figure 3)

NOTE: Failure to make waterproof connections and fuse pump properly
will void the product warranty.

Figure 2

Lock

Base Strainer

1/8" Pilot Holes

(3) #8 Fasteners

Pump Housing

Press Tab
To Unlock

Motor Cartridge Replacement

Lock

Motor
Cartridge
Tab

Unlock

Unlock