Figure 12- 18 – Agilent Technologies E8267D PSG User Manual

Page 282

Advertising
background image

268

Chapter 12

Peripheral Devices
N5102A Digital Signal Interface Module

Figure 12-18

Clock Setup Softkey Menu for a Parallel Port Configuration

The top graphic on the display shows the current clock source that provides the output clock
signal at the Clock Out and Device Interface connectors. The graphic changes to reflect the clock
source selection discussed later in this procedure. The bottom graphic shows the clock edges
relative to the data. The displayed clock signal will change to reflect the following:

clock phase choice

clock skew adjustment

clock polarity selection

2.

Press the

Clock Source

softkey.

From this menu, select the clock signal source. With each selection, the clock routing display in
the signal generator clock setup menu will change to reflect the current clock source. This will be
indicated by a change in the graphic.

3.

Select the clock source.

If External or Device is Selected

Press the

Clock Rate

softkey and enter the clock rate of the externally applied clock signal.

NOTE

The clock phase and clock skew may need to be adjusted any time the clock rate setting is
changed. Refer to

“Clock Timing for Phase and Skew Adjustments” on page 251

.

Inactive for Input mode

Active for only the Internal clock source selection

Inactive for clock rates below 25 MHz

Inactive for clock rates below

10 MHz and above 200 MHz

Advertising