Hook-up troubleshooting – Nitek VB31AT User Manual

Page 5

Advertising
background image

Hook-Up

Troubleshooting

PROBLEM

POSSIBLE

CAUSE


No video at receiver

Check that camera video and coax connections are correct

Check the Unshielded Twisted Pair cable for opens or shorts

Check that power supply is connected and outputting the

correct voltage

Check

that

all

power

connections

are

correct

Check that the camera is receiving power

Check

that

camera

power

meets

manufacturers

specifications



Ghost image to the right,

Check the cable for possible “T” taps or bridge taps and

Horizontal

smearing

remove

them


Video will not sync,

Twisted pair wires for video are reversed; correct wires on

wide white jagged area

UTP connection


For Tech Support Call 800-528-4343