Pvx164 common hookup diagram, Pvr164 common hookup diagram, Dc b a – Nitek PS115 User Manual

Page 2

Advertising
background image

PVX164 common hookup diagram

Installation (PS115 and PVX164)

The PS115 has five easy connect jacks for outputting power and is designed for use with

several different products, this section is for use with the PVX164. Each of the PS115 power
output ports can supply up to 80 watts of power. Connect the PS115 power outputs to the
PVR164, as shown in the diagram below, using the supplied jumper cables. Note that the
center connector is left unused.

Care should be taken not to overload the PS115 outputs but if an overload does occur, the
outputs are individually protected from over current by an auto-resetting fuse. To reset a
PS115 output remove the problem power connector from the PVX164. After fixing any over
load conditions, reconnect the power connector.

Refer to the PVR164 instruction manual for details on the additional connections.

PVX164

PS115

Installation (PS115 and PVR164)

The PS115 has five easy connect jacks for outputting power and is designed for use with several

different products, this section is for use with the PVR164. Each of the PS115 power output ports can supply up
to 80 watts of power. Connect the PS115 power outputs to the PVR164, as shown in the diagram below, using
the supplied jumper cables. Note that the center connector is left unused.

Care should be taken not to overload the PS115 outputs but if an overload does occur, the outputs are
individually protected from over current by an auto-resetting fuse. To reset a PS115 output remove the problem
power connector from the PVR164. After fixing any over load conditions, reconnect the power connector.

Refer to the PVR164 instruction manual for details on the additional connections.

PVR164 common hookup diagram

CLASS 2

POWER OUTPUT

24-29VAC 50/60 Hz

3 Amp Max.

120 VAC
50/60Hz

5 Amps

5 A 250V

RISK OF FIRE -

REPLACE FUSE

AS MARKED

CAUTION

CLASS 2

POWER OUTPUT

24-29VAC 50/60 Hz

3 Amp Max.

CLASS 2

POWER OUTPUT

24-29VAC 50/60 Hz

3 Amp Max.

CLASS 2

POWER OUTPUT

24-29VAC 50/60 Hz

3 Amp Max.

CLASS 2

POWER OUTPUT

24-29VAC 50/60 Hz

3 Amp Max.

19.0

5.0

1.710

1

2

3

4

DATA IN

DATA IN

D

C

B

A

+

-

DATA IN

DATA IN

DATA IN

DATA IN

DATA IN

DATA IN

+

-

+

-

+

-

1

2

3

4

1

2

3

4

1

2

3

4

1

3

+ -

+ -

+ -

+ -

2

4

1

3

+ -

+ -

+ -

+ -

2

4

1

3

+ -

+ -

+ -

+ -

2

4

1

3

+ -

+ -

+ -

+ -

2

4

PVR164

PS115

CLASS 2

POWER OUTPUT

24-29VAC 50/60 Hz

3 Amp Max.

120 VAC
50/60Hz

5 Amps

5 A 250V

RISK OF FIRE -

REPLACE FUSE

AS MARKED

CAUTION

CLASS 2

POWER OUTPUT

24-29VAC 50/60 Hz

3 Amp Max.

CLASS 2

POWER OUTPUT

24-29VAC 50/60 Hz

3 Amp Max.

CLASS 2

POWER OUTPUT

24-29VAC 50/60 Hz

3 Amp Max.

CLASS 2

POWER OUTPUT

24-29VAC 50/60 Hz

3 Amp Max.

+ -

+ -

2

4

+ -

1

+ -

3

POWER

1 - 4

VIDEO

1 - 4

DATA

+ -

+ -

6

8

+ -

5

+ -

7

POWER

+ -

+ -

10

12

+ -

9

+ -

11

POWER

+ -

+ -

14

16

+ -

13

+ -

15

POWER

5 - 8

VIDEO

5 - 8

DATA

9 - 12

VIDEO

9 - 12
DATA

13 - 16
VIDEO

13 - 16

DATA

Advertising