Background

Newer models of the Tracer 3202 outdoor unit will have 1.5 to 2 meters of twisted pair cable
(“pigtail”) preattached to the 3202 base. The twisted pair conductors are pre-stripped and ready
for crimping and attachment to a receptacle connector. A receptacle connector kit is available
that will mate to existing customer-end cable connectors used with the original 3202 model. The
contents of this kit include:

1 CPC (circular plastic connector) receptacle

1 CPC strain relief

4 receptacle crimping pins (male gender)

The instructions described in this document refer to the 3202 pre-attached cable only. For
instructions on attaching the plug connector to the customer cable, please consult the Tracer
2210/3202 System Manual (provided on the Tracer 2210/3202 Documentation CD).

Directions

Figure 1 shows a detailed view of the connector assembly required to attach the receptacle
connector to the pre-attached 3202 cable. The plug connector assembly is shown for reference
only.

















Figure 1 – Connector Assembly Diagram


The provided 3202 pigtail cable has heat shrink tubing on conductor pairs 1 and 2. Insert the 1,2
pair in the 1,2 slots in the receptacle, without regard to which conductor is wired to conductor 1
or conductor 2. Likewise, insert the 3,4 pair in the 3,4 slots in the receptacle, without regard to
which conductor is wired to conductor 3 or conductor 4.

1

2 3

4

Detail B – B

Detail A – A

A

A

1
2
3
4

1

2
3
4

P1 P2

Schematic

P1

P2

x 2

B

B

1

2 3

4

Plug Connector

(Customer end)

Receptacle Connector with Strain Relief

(3202 end)

3202 Pigtail Cable

Customer Cable