SPECIFICATIONS

Display:

¾”-High LCD

Accuracy:

± 1°C (0 to 40°C) otherwise ± 2°C ± 2%RH mid-range otherwise ± 4%RH

Resolution:

1°F or °C 1%RH

Temperature Range: 32 to 122°F (0 to 50°C)
Humidity Range:

25 to 95%RH

Memory:

Stores and recalls minimum/ maximum temperature and humidity readings.

Display up-dated every second

Functions:

Temperature and relative humidity

Attachments:

Wall mount, bench stand

Clock:

none

Size:

3¾” x 2½” x ½”

Weight:

3 oz.

Figure 1:

Description

1. Display

2. MAX-HYGRO

3. MIN-HYGRO

4. Memory/Clear

5. MAX-THERMO

6. MIN-THERMO

BEFORE USING
1.

To turn unit ON, remove the red protective tabs from the batteries.

2.

To open battery compartment, slide BATTERY COMPARTMENT DOOR on the
back of unit in direction of arrow.

3.

Remove red tabs. Re-insert batteries in appropriate positions to agree with the
polarity symbols (+ and -) in the battery compartment.

4.

Replace BATTERY COMPARTMENT DOOR.

Change Temperature Reading to Fahrenheit (F°) or Celsius (C°)
1.

Open BATTERY COMPARTMENT DOOR. (See above - Before Using.)

2.

Locate switch in upper right corner of battery compartment.

3.

Slide switch to left for Celsius (C°). Slide switch to right for Fahrenheit (F°).

4.

Replace BATTERY COMPARTMENT DOOR.

Thermometer Operation
1.

Press the THERMO-MIN button once to recall the minimum temperature stored in
the memory. “MIN” will appear on the display.

2.

Press the THERMO-MIN button once again to display the current temperature.
“MIN” will no longer appear on the display.

3.

Press the THERMO-MAX button once to recall the maximum temperature stored in
the memory. “MAX” will appear on the display.

4.

Press the THERMO-MAX button once again to display the current temperature.
“MAX” will no longer appear on the display.

Reset the Thermometer Memory
1.

Press the THERMO-MIN button once to recall the minimum temperature stored in
the memory. “MIN” will appear on the display.

2.

Press the MEMORY/CLEAR button once to reset the minimum temperature to the
current temperature.

3.

Press the THERMO-MIN button once again to display the current temperature.
“MIN” will no longer appear on the display.

4.

Press the THERMO-MAX button once to recall the maximum temperature stored in
the memory. “MAX” will appear on the display.

5.

Press the MEMORY/CLEAR button once to reset the maximum temperature to the
current temperature.

6.

Press the THERMO-MAX button once again to display the current temperature.
“MAX” will no longer appear on the display.

Hygrometer Operation
1.

Press the HYGRO-MIN button once to recall the minimum relative humidity stored
in the memory. “MIN” will appear on the display.

2.

Press the HYGRO-MIN button once again to return to the current relative humidity.
“MIN” will no longer appear on the display.




3.

Press the HYGRO-MAX button once to recall the maximum relative humidity stored
in the memory. “MAX” will appear on the display.

4.

Press the HYGRO-MAX button once again to return to the current relative humidity.
“MAX” will no longer appear on the display.

Reset the Hygrometer Memory
1.

Press the HYGRO-MIN button once to recall the minimum relative humidity stored
in the memory. “MIN” will appear on the display.

2.

Press the MEMORY/CLEAR button once to reset the minimum relative humidity to
the current relative humidity.

3.

Press the HYGRO-MIN button once again to display the current relative humidity.
“MIN” will no longer appear on the display.

4.

Press the HYGRO-MAX button once to recall the maximum relative humidity stored
in the memory. “MAX” will appear on the display.

5.

Press the MEMORY/CLEAR button once to reset the maximum relative humidity to
the current relative humidity.

6.

Press the HYGO-MAX button once again to display the current relative humidity.
“MAX” will no longer appear on the display.

DISPLAY MESSAGES
HHH – Three Hs flashing indicate the relative humidity being measured is above the

range of the unit.

LLL – Three Ls flashing indicate the relative humidity being measured is below the

range of the unit.

- - – Two dashes indicate the temperature, although still displayed, is above the range

of the unit.

MOUNTING THE UNIT
1.

To allow for different mounting positions, the white unit holder fits securely over
the top or bottom of the unit.

2.

Select the position and location where the unit will be mounted.

3.

Make sure the surface of the location is clean and smooth.

4.

Attach the unit to the selected location by removing the paper covering from the
adhesive tape on the back of the unit holder and pressing the unit firmly in place.

5.

The unit can be more permanently mounted by utilizing the two small screw holes
on the unit holder. (Screws are not included.)

BENCH STAND
1.

The bench stand is part of the BATTERY COMPARTMENT DOOR.

2.

Locate the small rectangular opening at the bottom of the BATTERY
COMPARTMENT DOOR.

3.

Insert paper clip into opening and gently turn ⅛” in either direction. Stand will flip
open.

4.

To close, snap the stand closed.

ALL OPERATIONAL DIFFICULTIES
If this unit does not function properly for any reason, please replace the batteries with two
new AAA alkaline batteries. (See “Battery Replacement” below.) Low battery power can
occasionally cause any number of “apparent” operational difficulties. Replacing the
batteries with fresh ones will solve most difficulties. Equivalent battery replacements are
any AAA alkaline batteries. Replacement battery Cat. No. 1105.

BATTERY REPLACEMENT
1.

To open battery compartment, slide BATTERY COMPARTMENT DOOR on the
back of unit in direction of arrow.

2.

Remove depleted batteries. Insert two fresh AAA alkaline batteries in appropriate
positions to agree with the polarity symbols (+ and -) in the battery compartment.

3.

Replace BATTERY COMPARTMENT DOOR.



WARRANTY, SERVICE, OR RECALIBRATION
For warranty, service, or recalibration, contact:

CONTROL COMPANY

4455 Rex Road

Friendswood, Texas 77546 USA

Ph. 281-482-1714 Fax 281-482-9448

E-mail [email protected]

www.control3.com

Control Company is ISO 9001 Quality-

Certified by DNV and ISO 17025

accredited as a Calibration Laboratory

by A2LA.

TRACEABLE

®

DIGITAL HUMIDITY/TEMPERATURE METER INSTRUCTIONS

Advertising