SPECIFICATIONS:

Flow:

120 milliliters to 2.2 liters per minute

Fluid Viscosity:

0 to 200 centipoises

Suction Lift:

3 meters wet, 10 centimeters dry

Acceptable Fluid
Temperatures:

–40 to 93

o

C

Acceptable Tubing: All types

Tubing Size:

Inside diameter of nominal 4.8 mm
(

3

/

16

inch)

Wetted Parts:

Dupont Delrin, 304 Stainless Steel, Viton, Dupont Teflon

Motor:

12 Volt DC Variable

Adaptor:

U.L. 120 VAC, 60 Hz, 47 W

Duty cycle:

Intermittent

Size:

20.3 x 12 x 11.5 cm (8 x 4 ¾ x 4 ½ inches)

Weight:

454 grams (1 pound)

CAUTION: Prior to use, a 'Chemical Resistance Chart' should be used to insure
that wetted pump parts will not be affected by chemical being pumped.

MAXIMUM FLOW RATES AT DIFFERENT HEAD PRESSURES

PSI Ft

H20 ml/min

fluid oz/min

0 0 2,200 78
5 12 2100 75
10 23

1750 63

15 35

1250 45

20 46

350 13

CONTROL PANEL
S1: Power/Direction switch: For selecting FORWARD, REVERSE, & power OFF
S2: Pump Speed switch: For selecting FAST, SLOW, and PRIME (PURGE)
C1: Variable Flow Control: For varying flow rate

CAUTION: During operation of the pump, the top panel or the black heat sink
on the back of the pump may be very warm to the touch.

OPERATION
1. Plug

the power supply into an electrical outlet.

2. Remove

red covers from the inlet and outlet barbed pump fittings.

3. NOTE:

To insure instant pumping place some liquid into pump inlet or outlet

fittings so it is wetted. (Prime pump by placing some liquid into the

barbed fitting. This can be done by squeezing a short piece of tubing
filled with liquid, an eyedropper, a bulb filled with liquid, blowing into
a short piece of tubing filled with liquid, or using a syringe.)

4. Slide

one end of a piece of tubing nominal 4.8 mm, inside diameter

(

3

/

16

-inch) over the barbed inlet pump fitting. Most users select nomi-

nal 4.8 mm (

3

/

16

”) inside diameter tubing. Place the other end of the

tubing into the vessel to be emptied.

5. Slide

one piece of tubing over the barbed outlet pump fitting. Place

the other end of the tubing into the vessel to be filled.

6. Move

Power/Direction switch (S1) to FORWARD to activate

pumping.

7. Move

the Pump Speed switch (S2) to Prime (Purge) to quickly fill

the tubing with liquid.

8. Move

the Pump Speed switch (S2) to SLOW or FAST.

9. Within each of the two speed ranges (SLOW and FAST), the flow

rate can be varied for precise delivery by rotating the Variable Flow
Control knob (C1). Selecting a higher reference number increases
the flow rate of the pump.

10. Use REVERSE (S1) to empty the liquid in the tubing back to a

vessel.

TROUBLESHOOTING
1. If

the pump sounds like it is pumping, but no liquid is moving, do

the following. Prime the pump by placing some liquid into the
barbed inlet fitting. This can be done by squeezing a short piece of
tubing filled with liquid, an eyedropper, a bulb filled with liquid,
blowing into a short piece of tubing filled with liquid, or using a
syringe.

2. If

the pump has been pumping at high speed for sometime, the

regulator chip may overheat and shut the unit down. Turn the pump
off and allow it to cool down.

3. If

the pump makes no sound when turned on, make certain there is

power to the outlet and the power supply is plugged in.

ACCESSORIES

Control Co.
Cat. No. 3280 Tight-Seal

TM

Hose/Tubing Clamp Assortment

Includes 5 each of 13 different sizes. Clamps have an inside diameter
from 6.2 mm to 41 mm (0.246 to 1.61 inches). Clamps securely fasten
tubing on connectors, pumps, glassware, and filtration units. Chemi-
cal-corrosion-resistant, rustproof, and nonconducting nylon is ideal for
use in the wide temperature range of 0 to 90

o

C (32 to 194

o

F).

Control Co.
Cat. No. 3285 Tight-Ties

TM

, Cable Ties Assortment

Includes 400 ties with lengths from 4 to 14 inches. One-piece, self-
locking, ties are made of chemical-corrosion-resistant, rustproof, and
nonconducting nylon, ideal for use in the wide temperature range of

–40 to 85

o

C (-40 to 185

o

F).

WARRANTY OR SERVICE
For warranty or service, contact:

Advertising