Resetting the system, Figure 3-20 resetting the system – Accton Technology ES3526XA User Manual

Page 78

Advertising
background image

Configuring the Switch

3-34

3

CLI – Enter the IP address of at least one SMTP server, set the syslog severity level
to trigger an email message, and specify the switch (source) and up to five recipient
(destination) email addresses. Enable SMTP with the logging sendmail command
to complete the configuration. Use the show logging sendmail command to display
the current SMTP configuration.

Resetting the System

Web – Click System, Reset to reboot the switch. When prompted, confirm that you
want reset the switch.

Figure 3-20 Resetting the System

CLI – Use the reload command to restart the switch. When prompted, confirm that
you want to reset the switch.

Note:

When restarting the system, it will always run the Power-On Self-Test.

Console(config)#logging sendmail host 192.168.1.200

4-50

Console(config)#logging sendmail level 4

4-51

Console(config)#logging sendmail source-email [email protected]

4-52

Console(config)##logging sendmail destination-email [email protected]

4-52

Console(config)#logging sendmail

4-53

Console(config)#exit
Console#show logging sendmail

4-53

SMTP servers
-----------------------------------------------
1. 192.168.1.200

SMTP minimum severity level: 4

SMTP destination email addresses
-----------------------------------------------
1. [email protected]

SMTP source email address: [email protected]

SMTP status: Enabled
Console#

Console#reload

4-23

System will be restarted, continue <y/n>? y