Control Company 4137 DUAL-CHANNEL THERMOMETER WITH COMPUTER OUTPUT User Manual

Control Company Thermometers

Advertising
background image

SPECIFICATIONS
Temperature Range:
-50 to 1999°F / -50 to 1230°C
Resolution:

0.1° or 1°

Accuracy:

±(0.75% + 1°C)

Sampling time: 1 second
Data output:

RS-232 interface

QUICK REFERENCE
On

Turns unit on.

Off

Turns unit off.

Data Hold “Freezes” the display at the current reading.
Memory Record

Activates the Record mode enabling minimum

and maximum readings to be recorded.

Memory Recall

Displays the stored minimum and maximum

temperature readings while in Record mode.

°F/°C

Switches display between °F and °C.

Function Permits viewing temperature channel readings

or differential temperature reading.

1.0°/0.1° Switches between 1° and 0.1° resolution

(0.1° available from -50.0 to 199.9).

TEMPERATURE MEASUREMENT
Single Probe measurement

Press the ON button to power unit.

1.

Select °F or °C by pressing the °F/°C button.

2.

Select 0.1° or 1.0° resolution by pressing the 1°/0.1°

3.

button.

Insert temperature probe into T1 socket. It may be

4.

necessary to press the FUNCTION button until “T1”
is displayed, indicating the unit is sampling from the
probe in the T1 socket.

Note: The cable and connectors are keyed, do NOT
insert connector incorrectly and force it.

Dual probe and differential measurement

Press the ON button to power unit.

1.

Select °F or °C by pressing the °F/°C button.

2.

Select 0.1° or 1.0° resolution by pressing the 1°/0.1°

3.

button.
Insert temperature probe into T1 socket and another

4.

temperature probe into T2 socket.

Note: The cables and connectors are keyed, do NOT
insert the cables incorrectly and force them.

Press the FUNCTION button to alternate between

5.

viewing temperature readings from probe T1, probe
T2, and the differential temperature. The FUNCTION
button alternates between the following settings:

When “T1” is displayed, the upper display indicates
temperature reading from T1 probe. The T2 probe
temperature reading appears on lower display.

When “T2” is displayed, the upper display indicates
temperature reading from T2 probe. The T1 probe
temperature reading appears on lower display.

When “T1 - T2” is displayed, the upper display indicates
differential temperature of T1 and T2 probes. The T1
probe temperature reading appears on lower display.

DATA HOLD FUNCTION

To “freeze” the display at the current temperature

1.

reading(s), press the DATA HOLD button (“D.H” will
appear along the top of the display).

Note: While in the Hold mode, pressing the °C/°F,
FUNCTION, 1°/0.1°, MEMORY RECORD, or MEMORY
RECALL button will have no affect and will not change
the “frozen” display.

Push the DATA HOLD button a second time to return

2.

to normal temperature sampling (“D.H will no longer
appear on the display).

MEMORY RECORD
Press MEMORY RECORD button to activate the Record
mode. Once the Record mode, the unit will begin
recording minimum and maximum temperature readings
achieved for the probe indicated on the main display
(“T1” or “T2”) (“REC” will appear along the bottom of the
display).
Note: The Automatic Shutoff feature is disabled while
in Record mode so that long-term monitoring may be
performed.

MEMORY RECALL

While in the Record mode, press the MEMORY

1.

RECALL button to recall the minimum and maximum
temperature recordings for the probe appearing on
the upper display (“T1” or “T2”).
The maximum temperature recording appears on the

2.

fi rst press of the MEMORY RECALL button (“Max”)
and the minimum temperature recording appears
on the second press (“Min”). A third press of the
MEMORY RECALL button returns the display to the
current temperature reading.
Exit the Record mode by pressing the MEMORY

3.

RECORD button.

Warning: The minimum and maximum temperature
recordings are automatically cleared once the Record
mode has been exited.

AUTOMATIC SHUTOFF
After 10 minutes, if no button has been pressed, the unit
will automatically shut off to preserve battery life. The
automatic shutoff can be overridden by entering the
Record mode (see “Memory Record” section).

COMPUTER OUTPUT
The meter features an RS-232 output which allows data
to be exported to a computer or data logger in real-time
via the accessory data acquisition software. (See the
“Accessories” section.)

TRACEABLE

DUAL-CHANNEL

THERMOMETER

WITH COMPUTER

OUTPUT

INSTRUCTIONS

®

DISPLAY MESSAGES
“LBT” indicates that the battery is low and needs replace-
ment (see “Battery Replacement” section)
“---” indicates the reading is outside the range of the unit.

ALL OPERATIONAL DIFFICULTIES
If this thermometer does not function properly for any
reason, please replace the battery with a new, high-quality
battery (see “Battery Replacement” section). Low battery
power can occasionally cause any number of “apparent”
operational diffi culties. Replacing the battery with a new
fresh battery will solve most diffi culties.

BATTERY REPLACEMENT
An erratic display, faint display, no display, or “LBT”
appearing on the display are all indicators that the battery
needs replacement. Remove the battery cover. Remove
the exhausted battery and replace it with a new 9-volt
alkaline battery. Replace the battery cover.

ACCESSORIES
Cat. No. 4136 Data Acquisition System Accessory

Powerful and easy to use computer data capture/data
logging program works with Traceable

®

Instruments with

computer output. Records interval readings from 1 to
10,000 seconds; displays minimum/maximum readings;
and utilizes an alarm mode that permits the user to be
notifi ed visually, audibly, and by email when an alarm is

triggered. Data is stored to a fi le that can be printed in
any report or spreadsheet format. Networking server/client
capability allows the captured data to be monitored on a
remote workstation and/or by email. It is designed to work
with Windows

®

98/Me/NT/2000/XP/Vista. Includes a CD,

a 6-foot cable (supplied USB and serial connections)
that plugs into the instrument and computer. Accessory
extension cables expand cable length to 300 feet.

Cat. No. 4325 Data Logger
Captures and stores up to 8000 bytes (over 1000 read-
ings). Readings may be taken at intervals from 1 second
to 99 hours. Stored readings may be downloaded to
any PC and viewed. Can be read as-is or imported to
spreadsheets, databases, and statistical programs.
Supplied complete with serial cable, software (Windows

®

),

and batteries. For use with Traceable

®

meters featuring

computer output.

Cat. No. 4008 Surface Probe Stainless-steel with
handle. Temperature range is -73 to 760°C.

Cat. No. 4014 Stainless Steel Probe Stainless-steel
with handle, triple purpose (liquids, air/gas, and semi-
solids), Temperature range is -50 to 700°C.

Cat. No. 4028 Beaded Probe Fast-Response, beaded
probe. Tefl on cable can withstand temperatures of -40 to
250°C continuous or 300°C short-term use.

Cat. No. 4138 Easy-Use Adaptor 115 VAC

Cat. No. 8039 Low-Temperature Probe Stainless-steel
with handle; triple purpose (liquids, air/gas, and semi-
solids). Temperature range is -240 to 220°C.

Cat. No. 8613 High-Temperature Probe Ten-foot-long
0.19” diameter braided metal wire cable with smooth tip
measures -73 to 982°C continuous, 1093°C short-term.

WARRANTY, SERVICE, OR RECALIBRATION
For warranty, service, or recalibration, contact:

CONTROL COMPANY

4455 Rex Road

Friendswood, Texas 77546 USA

Ph. 281 482-1714 • Fax 281 482-9448

E-mail [email protected] • www.control3.com

Control Company is ISO 9001 Quality-Certifi ed by DNV and

ISO 17025 accredited as a Calibration Laboratory by A2LA.

Control Company Cat. No. 4137

Traceable

®

is a registered trademark of

Control Company.

©

2009

Control Company. 92-4137-00 Rev. 2 05212009

Advertising