Pach and Company Quantum QR Series QR5-QR5FF-QR5IP-QR5IPFF Quick Guide User Manual

Warning

Advertising
background image













































 Missing Parts, contact Pach and Company 1-888-678-7224
 Defective system under manufacturer warranty,

call 1-888-678-7224 for advance replacement

24 Months warranty

for complete system

6 Months warranty

for Printed Circuit Board

Exit program, cancel call

25

Keypad beep
0= disable (default)
1=enable

Save program

26

Door beep
0= disable
1= enable (default)

00

Change master code (0000 is
default)

27

Talk time (060-240
second). Default=60
second

01

Add new forwarding tenant’s
directory

28

Unlock relay1 time
(12-99 second). Default=
12 second

02

Edit existing tenant’s directory

29

Unlock relay2 time
(12-99 second). Default=
12 second

03

Delete existing tenant’s
directory

30

Call Forwarding
0= disable 1= enable

04

Clear all forwarding tenant’s
directory

31

Call forwarding time
05-60 second

05

Call Forwarding

32

Forwarding directory
0-9

06

New access code

33

Temporary code

07

Delete access code

34

Special code

08

Clear all access code

35

Temporary card

09

Access code digit (4-8 digit).
Default is 4-digit

36

Special card

10

Add new card

37

Initiate premise call
0=**, 1=## (default)

11

Delete card

38

System acknowledge
(0-9). Default= 3

12

Clear all card

39

Remote access
0= disable
1=enable (default)

13

Set time

40

DTMF relay 1 (1-9).
Default=9

14

Set date

41

DTMF relay 2 (1-9).
Default=8

15

Initializing event recording

42

Relay 2 Mode

1= door control (default)
2= relay 2 trigger
simultaneously as relay 1
3= enable if function code 24
is enable
4= turn relay 2 on and off
On=7, Off=6

16

AUS= auto unlock schedule
(0-9 schedule)

43

DND: do not disturb time
zone (0-9)

17

TMZ= time zone. 20 TMZ, 00-
20.

44

Disable Time zone relay
1, 2 or both

18

HLD= holiday zone. 20 HLD,
1-20

45

Relay 1 and 2 unlock
timer

20

AUXIN1

0= disable (default)
1= enable control by relay 1 open
interval
2= relay 1 control by AUXIN1

46

Firmware version

21

AUXIN2

0= disable (default)
1= enable control by relay 2 open
interval
2= relay 2 control by AUXIN2

48

PBX enable. Default=
disable

22

Do not disturb
0= disable (default), 1= enable

23

Lock-out Count

49

Edit Access code

24

Alarm

0= disable
1= local beep for 60 seconds
2= disable system for 60 seconds
with no beep
3= call directory (0-9)

50

Erase the memory to
factory default

51

Welcome screen

Log on to programming: Press

and

simultaneously then release, the

welcome message will stop scrolling
(repeat if screen still scrolls) enter 4-digit

MASTER CODE

” (0000 is default), the

screen will show:

Select the “

Function Code

” from the table

OPERATION

Opening the door remotely

press

(relay 1) or

(relay 2)

Opening the door with the access code

press

(display screen

will stop scrolling) then press a valid 4-digit access code.

Extending talk time

tenant must press

from the phone after the

time out warning beep.

Calling into the system from premise location (Intercom)

1. Press

or

depending on function code 37, then

press

to communicate with the person

Calling into the system from remote location

:

Enable function code 39
1. Call the system phone number, hear one beep if the system

answering the call.

2. Press

then 4-digit master code, hear one short beep

3. Press

to establish two way communication

4. Press

or

to release the door.

Call waiting:

function code 38 must be set 1-9 and function code 39

can be set either 1 or 0, press

on your phone to transfer between

calls

See Function Code 37
Premise

Relay 1

Relay 2

Open cycle

##9/**9

##5/**9

Open hold

##8/**8

##4/**4

Close ##7/**7

##3/**3

OPERATION

TO CALL FROM THE SYSTEM

1. INTERCOM MODE PRESS

2. CALL FORWARDING MODE, press

to scroll name from A-Z or

to scroll name from Z-A then press

to call name selected.

Opening the door remotely

press

(relay 1) or

(relay 2)

WARNING:

DO NOT USE ON BOARD 12VDC

and GND TO POWER A DOOR STRIKE OR
MAGNETIC LOCK

SEPARATE POWER MUST BE USED TO POWER
A DOOR STRIKE OR MAGNETIC LOCK.

Advertising