Flush out supply lines; fig. 6, 4 left or right hand installation; fig. 7 – American Standard SELECTRONIC 6065.565 User Manual

Page 5

Advertising
background image

4

M968699 Rev. 1.15

1

CLOCKWISE CLOSES

CONTROL STOP

COUNTER-CLOCKWISE

OPENS CONTROL STOP

REMOVE COVER

Fig. 6

1. Remove COVER (1) from SUPPLY STOP (2).

2. With a flat blade screwdriver open SUPPLY STOP (2).

3. Turn on water supply to flush line of any debris or

sediment.

4. Close SUPPLY STOP (2) and replace COVER (1).

FLUSH OUT SUPPLY LINES; Fig. 6

4

3

The UNIT is shipped with the inlet flange on the right
side. If needed, the orientation can be reversed by
following the steps below.

1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (4)

in back of top half of FLUSH VALVE

(2). Fig. 7a.

2. Rotate TOP (2) to the right and pull off. Fig. 7b.

3. Rotate bottom half of FLUSH VALVE (3) 180˚. Fig. 7b.

4. Replace TOP (2) and rotate until key engages than

tighten SET SCREW

(1). Fig. 7c, 7d.

4 LEFT OR RIGHT HAND
INSTALLATION; Fig. 7

5

2

2

1

4

Fig. 7a

Fig. 7c

Fig. 7d

Fig. 7

4

KEY

2

2

1

3

Fig. 7b

180˚

2