48

Restoring Original Factory Default Settings

You can restore the original factory default settings for the ACS1208A /
ACS1216A. The original password for the default administrator account is
restored; all administrator and user accounts are removed from the system.
Only the station name and date and time are retained. This procedure requires
the use of a jumper cap.

1. Turn off the ACS1208A / ACS1216A and unplug the power cord.

2. Remove the cover of the ACS1208A / ACS1216A.

3. Place a jumper cap over pins 1-2 of the J18 jumper on the mainboard.

4. Plug in the power cord and turn on the ACS1208A / ACS1216A. The

following directions appear on the KVM console screen:

USERNAME AND PASSWORD INFORMATION AND PORT/USER

INFORMATION HAS BEEN CLEARED. PLEASE POWER OFF THE

SWITCH, REMOVE THE JUMPER, CLOSE THE CASE, THEN

RESTART.

5. Turn off the ACS1208A / ACS1216A and unplug the power cord.

6. Remove the jumper cap from pins 1-2 of the J18 jumper.

7. Replace the cover on the KVM switch. Plug in the power cord and turn on

the ACS1208A / ACS1216A.

8. You should now use the default username and password to log in to the

ACS1208A / ACS1216A.