Aube Technologies Power Base PB1 30-024T User Manual

Installation guidelines, Introduction, Technical specifications

Advertising
background image

Installation Guidelines

Cut power to the heating system at the main power panel to
avoid electrical shock. Installation should be carried out by an
electrician.

For a new installation, choose a location about 5 ft. (1.5 m)
above the floor.
The thermostat should be installed facing the heating system
and on an inside wall.
Avoid locations where there are air drafts (top of staircase, air
outlet), dead air spots (behind a door), direct sunlight or con-
cealed chimneys or stove pipes.

PB1 30-024T

Installation Instructions

24 V Low Voltage Power Base

AUBE TECHNOLOGIES INC. TWO (2) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a two-year period following
the initial date of purchase. During this period, AUBE Technologies Inc. will repair or
replace, at our option and without charge, any defective product which has been used
under normal conditions.
The warranty does not cover delivery costs and does not apply to products poorly
installed or randomly damaged following installation. This warranty cancels and replaces
any other manufacturer's express or implied warranty as well as any other company
commitment.
AUBE Technologies Inc. cannot be held liable for related or random damages following
the installation of this product. The defective product as well as the purchase invoice
must be returned to the place of purchase or mailed, prepaid and insured, to the
following address.

Introduction

The PB130-024T power base is designed to power a TH13X Series
control module. This low voltage power base can be used to drive a
line voltage load using a relay or connect directly to equipment (such
as a hot water system) using a 24 V signal.
Although the PB130-024T is compatible with most relays, it has been
optimized for use with an Aube relay. Aube offers triac relays (SSR)
such as the RT850 and RT850T (with built-in 24 V transformer), and
electromechanical relays such as the RC840 and RC840T (with built-
in 24 V transformer).

Technical Specifications

Maximum load

: 0.5 A / 24 VAC

Operating temperature

: 32°F to 122°F (0°C to 50°C)

Storage

: -4°F to 122°F (-20°C to 50°C)

Size (H • W • D)

: 2.94 x 2.94 x 0.53 in. (74.6 x 74.6 x 13.3 mm)

Wire gauge

: 14 to 22 AWG

Installation Steps

n

Connect the base. See the typical wiring diagrams.

a) Electric heating (figures 1, 2 and 3)

• Connect the base to the relay:

• Use a relay with a built-in 24 V transformer or
• Use a relay and an external 24 V transformer.

• Connect the relay to the load (see relay’s instructions).

b) Hot water heating (figure 4)

• Connect the base to the 24 V valve of the

water heating system.

o

For a floor heating installation, connect the
floor sensor between the S and R terminals.

p

Push the excess wire into the wall and secure the
base using the provided screws and wall anchors.

q

Before

mounting the control module onto the base, select the

heating cycle, set the switches (if necessary) and mount the
control module. Refer to the control module’s user guide for
more information.

r

Once the control module is configured (switches) and installed,
return power to the heating system.

If you have any questions concerning the PB130-024T low
voltage power base, call our technical support team at:

Included Parts

n

One (1) PB130-024T low voltage power base

o

Two (2) anchors

p

Two (2) mounting screws

14/11/2003 400-130-002-B

705 Montrichard
Saint-Jean-sur-Richelieu
Quebec, Canada J2X 5K8

Tel.: (450) 358-4600
Toll Free: 1-800-831-AUBE
Fax: (450) 358-4650
Email: [email protected]

10 rue Ampère
95500 Gonesse
France

33 (0) 1 34 07 99 00

33 (0) 1 34 07 99 19
[email protected]

For more information on our products, visit us at:

www.aubetech.com

Advertising