Leakage checkpoints – A.O. Smith 185762-000 User Manual

Page 19

Advertising
background image

19

LEAKAGE CHECKPOINTS

Read this manual fi rst. Then before checking the water heater
make sure the electrical power supply has been turned “OFF” before
checking the tank for leakage.

*A. Condensation and dripping may be seen on pipes if the water

temperature is low in humid weather or pipe connections may
be leaking.

*B. The anode rod fi tting may be leaking.

C. Small amounts of water from temperature-pressure relief valve

may be due to thermal expansion or high water pressure in your
area. If the valve is not piped to an open drain the released
water could be mistaken for a leaking heater, see “Thermal
Expansion” section.

*D. The temperature-pressure relief valve may be leaking at the

tank fi tting.

E. Water on the side of the tank may be condensation due to the

panel or insulation not being in place.

F. Water from a drain valve may be due to the valve being slightly

opened.

*G. The drain valve may be leaking at the tank fi tting.

*H. Water in the water heater bottom or on the fl oor may be from

condensation, loose connections, or the relief valve. DO NOT
replace the water heater until a full inspection of all possible
water sources is made and necessary corrective steps taken.

Leakage from other appliances, water lines, or ground seepage

should also be checked.

* To check where threaded portion enters tank, insert cotton

swab between jacket opening and fi tting. If cotton is wet, follow
“Draining” instructions in the “Periodic Maintenance” section
and then remove fi tting. Put pipe dope or tefl on tape on the
threads and replace. Then follow “Filling the Water Heater”
instructions in the “Installing the New Water Heater” section.

FIGURE 23.

A

B

A

C

D

E

G

F

H

6” (152.4 mm)
MAXIMUM AIR
GAP

Advertising
This manual is related to the following products: