Pp3_14.eps, Power probe 3 specifi cations, Peak to peak mode – Power Probe 3 User Manual

Page 14: Circuit breaker

Advertising
background image

13

Power Probe 3 Specifi cations

DC 0 – 70V + 1 digit

P-P 0 – 70V

Frequency response of tone pass through

10Hz to greater than 10 Khz

PP display

15Hz Square Wave

35Hz Sine Wave

Power Probe Mode – Continuity to ground

First level – display is enabled less than 20K

Second level – green LED is enabled less than 2K

– & + Peak Detector Response

Single event capture less than 200µs pulse width

Repetitive events less than 1µs pulse width

Peak to Peak Mode

0 – 70V + 1 digit

4Hz to over 500kHz Square Wave input

4Hz to over 250kHz Sine Wave input

Threshold for PPAC/Audible passthrough

Circuit Breaker

8 amp thermal response – Manual reset

Typical Response

8 amps 10 amps 15 amps 25 amps Short Circuit
No trip 20 min. 6 sec. 2 sec. 0.3 sec.

.1 0.3 2 sec. 6 sec. 20 min.

Short

Circuit

25 amps

15 amps

10 amps

8amps

Advertising