Troubleshooting guide – Poweramp VS VERTICAL SPECIALTY 5.2007 User Manual

Page 16

Advertising
background image

The VS dockleveler shuts off before
prop is fully engaged

1. Prop limit switch misadjusted

1. Adjust (fig. 4) so that switch

activates when prop is fully
extended.

The VS dockleveler will not

lower.

1. Locking device in place.

2. Lowering speed control shut

off.

1. Reposition locks in unlock

position (See figs 4 & 5).

2. Locate valve, open slightly.

Adjust accordingly.

The VS dockleveler lowers too fast.

1. Down speed adjustment

improper.

The VS dockleveler motor runs continu-
ously

1. 1 phase unit only--contractor

stuck on.

1. Locate and replace.

1. Setting can be decreased by

turning knurled knob (CW),
adjust to suit.

The VS dockleveler lowers without
depressing button.

1. Float switch misadjusted.

1. Adjust so switch is active only

when VS leveler is approxi-
mately 6" above horizontal
position.

Lip will not fold.

1. Debris in hinge line.

2. Solenoid valvbe stuck.

1. Clean hinge, remove debris.

2. Remove and check valve and coil

for proper operation. Clean,
replace if necessary.

Lip will not extend.

1. Debris in hinge line.

2. Solenoid valve stuck.

1. Clean hinge, remove debris.

2. Remove and check valve and

coil for proper operation. Clean,
replace if necessary.

Problem

Cause (s)

Solution (s)

15

Troubleshooting Guide