PROLiNK PDC50 50W DC UPS User Manual

Installation & initial startup, Pdc 50- dc ups quick guide

Advertising
background image

V . 1 . 1

I n t r o d u c t i o n

The UPS is exclusively designed for communication devices such as hub, switch and

modem. Featuring with dynamic voltage regulator, the UPS can ensure stable DC

power to connected loads as utility. The built-in DC start function enables the UPS

to be started up without a supply of AC power. The main features of this UPS are

listed below:

1

2

Fr ont V iew :

3

NOT E : Before installation, please inspect the unit. Be sure that

nothing inside the package is damaged.

P la cement & Stora ge Conditions

Install the UPS in a protected area that is free of excessive dust and has adequate

air flow. Please place the UPS away from other units at least 20 cm to avoid

interference. Do NOT operate the UPS where the temperature and humidity is

outside the specific limits. (Please check the specs for the limitations.)

Connect to U tility and Cha r ging

Before initial use, please plug in the AC input cord to the

wall outlet and turn on the UPS for charging. For the best

results, suggest to charge the battery at least 6 hours

before initial use. The UPS charges its battery while

connecting to the utility with power on.

Connect the Loa ds

There are two options for output terminals: 6VDC/12VDC and 12VDC/24VDC. Please

verify acceptable voltage of connected device before connecting the wires. Then

follow terminal printing to connect the positive and negative terminals to the devices.

T ur n On/ Off the Unit

Turn on the UPS unit by pressing and holding the power switch for 4 seconds. Turn

off the UPS unit by pressing and holding again the power switch for 4 seconds.

Connected devices will be protected by the UPS when turning on the UPS.

Indica tor s & A lar m Table for Oper ation

B a ck V iew :

6 hours

P r o d u c t O v e r v i e w

AC input
2 x DC (2 x 12 VDC) output screw terminals:
(see output options table)

1
2

2

1

Dual DC outputs

Microprocessor controlled guarantees high reliability

Compact size for standing and mounting flexibility

Supports solar powered devices and communication applications

Auto restart while AC is recovering

Off-mode charging

Overload protection and short circuit protection

Power switch
AC mode indicator: green lighting
Battery mode indicator:
yellow lighting indicates battery mode
yellow flashing indicates low battery
Fault indicator: red lighting

1

2
3

4

1

2

3

4

20c m

20c m

Conditions Visual Indications Alarm

Off

Sounding every 10 seconds

Green LED lighting

Yellow LED lighting

AC mode

Battery mode
Low battery at

battery mode
Fault Red LED lighting Continuously sounding

Yellow LED flashing

Sounding every second

PDC 50- DC UPS Quick Guide

Installation & Initial Startup

Advertising
Table of contents