Ariens SNO-THRO 926103-ST1332LE User Manual

Page 11

Advertising
background image

GB - 11

6. Insert the chute lock cable fitting into the bracket

on the chute pedestal, and then connect the
chute lock cable to the lock teeth by fitting the
cable ball end into the slot on the lock teeth.

NOTE: Press down on lock teeth with your finger to
align the cable ball end with the slot.

7. Replace the gear cover removed in step 1.

IMPORTANT: Rotate the discharge chute to the left
when tightening the pedestal hardware to ensure
clearance between the discharge chute and the belt
cover.

8. Tighten pedestal hardware to 15–31 lbf-ft

(20-42 N•m).

9. Make sure the discharge chute rotates left and

right when you push the discharge chute control
lever left and right.

Deflector Remote

NOTE: Connect the cable end to the cable anchor on
the discharge deflector before clipping the cable to the
cable bracket on the discharge chute.

1. Route deflector remote cable along the left side of

the chute pedestal.

2. Insert the barrel on the cable end into the bracket

on left side of chute deflector (Figure 9).

3. Hold seal out of the way while routing the cable

through the bracket on the left side of the
discharge chute, and then push the cable fitting
into the bracket.

4. Push the seal securely over the end of the cable

fitting to prevent water from entering the cable.

5. Check deflector travel. Adjust nut on cable end

under handlebar to obtain full travel, if necessary.
(See Deflector Remote on page 24.)

Figure 8

OS7270

Figure 9

1. Cable Anchor
2. Cable End
3. Deflector Cable
4. Cable Fitting
5. Cable Bracket

1

2

3

5

4

3

OS7070

Advertising