ADTRAN HTU-C / 3192 User Manual

Htu-c / 3192, Htu-c

Advertising
background image

HTU-C / 3192

CLEI: T1L4SNSC_ _

JOB

A

ID

61245004L6-22B

0104

CIRCUIT BOARD ROTARY SWITCH - SW2

Selects the DSX-1 Line Build Out

0..........0 - sets LBO to 0-133 feet

1..........133 - sets LBO to 133-266 feet

2..........266 - sets LBO to 266-399 feet

3..........399 - sets LBO to 399-533 feet

4..........533 - sets LBO to 533-655 feet

Note: Positions 5,6 & 7 are not used.

CIRCUIT BOARD JUMPER - P1

Selects the span powering voltage

LV (–140 Vdc)

Used to span power circuit with 0 or 1 HRE

HV (–190 Vdc)

Used to span power circuit with multiple HREs

CIRCUIT BOARD JUMPER - P3

Selects the framing of the HDSL circuit

UNF

HTU-C operates in unframed mode

AUTO

HTU-C auto detects framing

DSX EQ BANTAM JACKS

Provides an intrusive test access point to the data stream

TX

Accesses the data stream being received from the local loop

RX

Accesses the data stream being transmitted to the local loop

RS-232 DB-9 CONNECTOR

Used to access performance monitoring data, perform loopbacks and provision units

via VT100 emulation software such as Hyper Terminal – Private Edition and

ProComm Plus.

Provision terminal port as follows:

Data Rate — 19.2 kbps
Asynchronous Data Format — eight data bits, no parity (none), one stop bit

When using a PC with terminal software, be sure to disable any power saving

programs.

WARRANTY

Warranty for Carrier Networks products manufactured by ADTRAN and supplied
under Buyer’s order for use in the U.S. is ten (10) years. For a complete copy of
ADTRAN’s U.S. Carrier Networks Equipment Warranty:
(877) 457-5007, Document #414.

TX

RX

HTU-C

1245004L6

LP1

H

D

S

L

LP2

DSX

ALM

LBK

EXT ALM

LBK

TM OUT

DIS

BZS

T1

DIS

EN

AMI

FT1

EN

R

S

2

3

2

C

L

O

S

AIS
LBK
CDI

HTU-C / 3192

STATUS LEDs

LP1 / LP2

OFF

No synchronization between the HTU-C and the next
HDSL unit (HRE or HTU-R) on loop1 / loop2

RED

Poor signal quality on loop1 / loop2

YELLOW

Marginal signal quality loop on loop1 / loop2

GREEN

Good signal quality on loop1 / loop2

✷ FLASHING

Error detected at HTU-C or HTU-R

DSX

OFF

DSX-1 signal not detected

FLASHING

BPV, Frame Error (SF), CRC Error (ESF) is detected

GREEN

DSX-1 signal is present and synchronized

ALM

OFF

No alarm condition detected

RED

Local alarm condition detected (HTU-C), or local and
remote alarm condition detected (HTU-C and HTU-R)

YELLOW

Remote alarm condition detected (HTU-R)

LBK

OFF

No active loopback

FLASHING

Armed but not in loopback

YELLOW

Local loopback is active

FACEPLATE SWITCH - SW1

Selects response of HTU-R upon Customer Loss of Signal

AIS

HTU-R generates unframed all 1s toward network upon loss of customer signal

LBK

HTU-R generates loopback towards network upon loss of customer signal

CDI

HTU-R generates framed all 1s toward network upon loss of customer signal

FACEPLATE SWITCH - SW3

Loopback Timeout

Enabled

Loopback timeout is enabled

Disabled

Loopback timeout is disabled

Manual Line Code Select

AMI

AMI line code is selected

B8ZS

B8ZS line code is selected

Latching Loopback

T1

Allows only standard T1 testing

FT1

Allows for fractional T1 testing

External Alarm

Enabled

External alarm is enabled

Disabled

External alarm is disabled

COMPLIANCE CODES

This product complies with UL 1459, third
edition. It is intended to be installed in an
enclosure with an Installation Code (IC) of
“B” or “E” and in Restricted Access Locations
only. Input current at maximum load is 1 A,
and maximum output at overcurrent condi-
tion is 160 mA at -188 Vdc.

Code

Input Output

Installation Code (IC)

A

Telecommunication Code (TC)

X

Power Code (PC)

F

C

For complete Installation and Maintenance: (877) 457-5007, Document #300. Please have your fax number available.

C A U T I O N

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

Advertising