T31 TUNER

FM Section

Tuning range

87.5 to 108.0MHz

Frequency steps

50kHz

Presets: total/direct access

30/16

Sensitivity (IHF) for 50dB S/N ratio

typically 3µV

Alternate channel selectivity

better than 60dB

Capture ratio

1.5dB

Frequency response

20Hz–15kHz ±1dB

Ultimate S/N ratio (CCIR) Mono

better than –75dB

Stereo

better than –70dB

Total harmonic distortion

(96MHz reference, 22.5kHz deviation at 1kHz)

Mono

better than 0.1%

Stereo

better than 0.2%

Channel separation (1kHz)

better than 40dB

Pilot tone suppression

better than 60dB

Output level

700mV at 75kHz deviation

AM Section

Tuning range:

10kHz step; 530 to 1710 kHz

9kHz step; 531 to 1602 kHz

Presets

16

Usable sensitivity

typically 30µV

IF rejection

> 36dB

S/N ratio (30% mod., 50mV I/P)

> 38dB

Total harmonic distortion (30% mod., 50mV I/P)

< 3%

Output level

300mV at 70% modulation

Control inputs

IR remote standard

Philips RC-5, 36kHz carrier

IR in signal level

4–15V pk-pk

Trigger operating voltage

9–15V DC

Trigger in polarity

tip positive

General

Output impedance

220Ω

Minimum recommended load

5kΩ

Power consumption

10VA

Size W x D x H

430 x 290 x 85mm

Weight net

3.8kg

Weight packed

6.0kg

Supplied accessories

FM dipole aerial

AM loop aerial

mains lead

CR-389 remote control handset and batteries

E&OE

CONTINUAL IMPROVEMENT POLICY

Arcam has a policy of continual improvement for its products. This
means that designs and specifications are subject to change without
notice.

NOTE: All specification values are typical unless otherwise stated.

Advertising