Tools needed for calibration procedure, Calibration procedure – Server BS/BSA (05020 ) THERMOSTAT User Manual

Page 3

Advertising
background image

3

INsTAll INNer Vessel IN sHroUd. reassemble

unit, reversing disassembly procedures above.

If unit previously included a small rubber grommet

on thermostat shaft hole, remove and discard it.

4

INsTAll NeW THermosTAT KNoB BY AlIGNING

KNoB GrooVe WITH sPlINe oN NeW

THermosTAT sHAfT, THeN PUsH KNoB oNTo

sHAfT. (Tighten knob setscrew if used.)

5

seT UNIT UPrIGHT oNTo ITs feeT ANd PlUG

UNIT INTo PoWer soUrCe.

6

CAlIBrATe UNIT Per CAlIBrATIoN

INsTrUCTIoNs.

Factory-installed thermostats are sealed

after calibration.

do not attempt to calibrate a factory-installed

thermostat.

TOOLS nEEdEd FOR

cALIBRATIOn PROcEdURE

Hexagonal Wrench or Allen Wrench (1.5 mm)

-included in thermostat kit

dial Thermometer (stem type)

-to measure water temperature from

90

°

to 170

°

f (32.2

°

-76.7

°

C)

Cover (with hole in it)

-to contain heat within unit and to hold

the dial Thermometer.

cALIBRATIOn PROcEdURE

1

AlIGN KNoB oNTo THermosTAT sHAfT ANd

Press KNoB oNTo sHAfT.

2

TUrN KNoB To seTTING of:

135

°

F (57.2

°

c)

3

CArefUllY remoVe KNoB WITH sTrAIGHT PUll

To AVoId TUrNING THermosTAT sHAfT.

4

PlACe CoVer (WITH Hole IN IT) oVer UNIT

ANd INserT THermomeTer THroUGH CoVer

oPeNING.

5

TUrN UNIT oN ANd AlloW UNIT To HeAT UP To

A mINImUm of: 145

°

F (62.8

°

c)

The above “Heat Up-To” temperature is

considered a minimum temperature because

exceeding the temperature will not affect the
final calibration.

6

If THe TemPerATUre does NoT reACH THe

mINImUm “HeAT UP To” TemPerATUre,

Hold THe THermosTAT sHAfT WITH oNe HANd

ANd roTATe THe CAlIBrATIoN sCreW 1/2 TUrN

CoUNTerCloCKWIse, UsING THe sUPPlIed

WreNCH. Continue to repeat the 1/2 turn of the

calibration screw, until the temperature reaches

the minimum.

7

WHeN THe TemPerATUre reACHes THe

mINImUm “HeAT UP To” TemPerATUre,

TUrN CAlIBrATIoN sCreW TWo fUll TUrNs

CloCKWIse.

8

AlloW APPlIANCe To Cool To:

135°F (57.2°c)

If unit does not cool to the above “Cool To”

temperature, turn calibration screw two

additional full turns clockwise.

9

WHeN THe TemPerATUre reACHes THe

“Cool To” TemPerATUre, TUrN CAlIBrATIoN

sCreW CoUNTerCloCKWIse UNTIl A sofT

AUdIBle ClICK Is HeArd (oN). The unit will now

start and continue to heat up until another audible

click is heard (off), this second click indicates that

the heating has stopped.

J

rePeAT sTePs 6 THroUGH 10 UNTIl THe

AUdIBle ClICK Is CoNsIsTeNTlY HeArd WHeN

THe KNoB Is TUrNING BeTWeeN:

142°F (61.1°c) and 152°F (66.74°c)

K

seCUre THe CAlIBrATIoN sCreW BY PlACING

sUITABle THreAd-loCKING mATerIAl, sUCH As

loCTITe, IN THe sHAfT CeNTer.

L

AlIGN KNoB oNTo THermosTAT sHAfT ANd

Press KNoB oNTo sHAfT. If unit includes a knob

guard, install knob guard.

M

re-CHeCK seTTING ANd reTUrN UNIT To

serVICe.

Clockwise rotation of the calibration screw lowers

operating temperature.

Counterclockwise rotation of the screw raises the

operating temperature. rotation of the knob or

the thermostat shaft does just the opposite.

Thermostat shaft

Knob

Removed

Wrench

Turn calibration screw, using wrench,

CoUNTerCloCKWIse for steps 7 and 10.

Turn calibration screw, using wrench,

CloCKWIse for steps 8 and 9.

Advertising