Server PUMPING SYSTEM (85883/85885) User Manual

Page 2

Advertising
background image

U

nit

C

leaning

NOTE: FOR PUMP DISASSEMBLY AND CLEANING see:

PUMP INSTRUCTION MANUAL.

CLEANING

Before first use and after use daily, disassemble and clean unit. Stainless

steel parts can corrode. It is important to clean, rinse, sanitize, and dry these

parts daily and properly. Failure to comply with any of these instructions may

void unit warranty:

1

SEE UNIT DISASSEMBLY.

Do not use any highly alkaline or acidic solvents, steel wool,
or other harsh abrasives to clean unit.

Do not use abrasive cleansers, scrapers, steel pads, steel wool,
or other cleaning tools that can scratch surfaces.

A general purpose, nonabrasive cleaner may be used on hard
to remove food deposits.

A mildly abrasive nylon or brass brush may be used to remove
any food or mineral deposits on the unit.

Abrasive cleansing agents can corrode stainless steel.

Fully rinsing all parts can help prevent corrosion.

A nontoxic glass cleaner may be used for cleaning any
stainless steel parts and the dome.

2

Wipe external surfaces of unit with a clean damp cloth daily. Dry with a

clean soft cloth.

3

CLEAN AND SANITIZE ALL SURFACES IN CONTACT WITH FOOD

PRODUCT. Hose can be rinsed free of residual condiment by running

water through it in a sink. Clean out any remaining food procuct with

the brushes supplied with unit.

4

REMOVE AND WASH pump, hose, fittings, in warm soapy water. Rinse

thoroughly and dry with a soft clean cloth.

Use supplied brushes to clean all confined areas.

5

Sanitize parts following your local sanitization requirements.

ALL PARTS IN CONTACT WITH FOOD MUST BE SANITIZED.

ALLOW PARTS TO FULLY AIR DRY AFTER SANITIZATION.

Various elements and minerals, such as chlorides in tap water, can

accumulate on stainless steel parts and create corrosion.
To prevent corrosion on any stainless steel parts, it is important

to fully air dry, as required after sanitization, or to fully dry with a

clean soft cloth regularly.

s

afety

g

Uidelines

According to food and safety regulations, most foods must be stored and/or served

at certain temperatures or they could become hazardous. Check with your local

food and safety regulators for specific guidelines.

Be aware of the product you are serving and the temperature the
product is required to maintain. Server Products, Inc. can not be
responsible for the serving of potentially hazardous product.

NSF International lists this pump as: “Not acceptable for
dispensing potentially hazardous foods.”

s

erviCe

Contact your dealer or Server Products Inc. customer service department for the

following:

ORDERING REPLACEMENT PARTS

Be prepared to give this information:

1

Model Number

2

Series Number

3

Part Description

4

Part Number

You can find the unit model number, series number, and other specific data stamped

on the bottom or back side of every unit.

General Service, Repair, or Returns

Before sending any item to Server Products for service, repair, or return, contact Server

Customer Service to request a Return Authorization Number. Merchandise must be sent

to Server with this number and will be subject to a 20% (percent) restocking charge.

Returned goods must be in new and unused condition and not more than 90 days old.

Electrical parts (thermostats, heating elements etc.) are not returnable.
Server Products maintains a fully staffed service department with highly skilled factory

trained personnel. Service is extremely prompt. Under normal circumstances, a repaired

unit is shipped out the day after it is received. Labor charges are reasonable.

Server Products Limited Warranty

All Server Products equipment is backed by a two-year limited warranty against defects

in materials and workmanship. For complete warranty information go to:

www.server-products.com

85204

85883

POUCH SUPPORT, CRYOVAC*

85863

ALL

TOWER ASSEMBLY, 5 1/2”

85865

ALL

CONDIMENT PUMP REMOTE PUMPING

85866

85883

KIT, HOSE, 30” CRYOVAC

85867

85885

KIT, HOSE, 30” VOLUME

85895

85885

POUCH SUPPORT, VOLUME*

* SEE OPPOSITE PAGE

Part #

Model

Description

Cutout Template for Remote Pumping System

TO CENTER SCREW HOLES

.281 DIA SCREW HOLES

DIM FOR OPENING

5.625 “

.500 “ R

5.375 “

3.00 “

3.00

800-558-8722

262-628-5600

[email protected]

7

262-628-5110

01883-REVB-021011

85865

85863