SPP Pumps Auto Prime Medium Head Open Set - AC50-75 Range User Manual

SPP Pumps Pumps

Advertising
background image

5.

Key Parts

Delivery

Fuel
Tank
Filler

Exhaust
Silencer

Engine
Oil Filter

Engine Oil
Filler and
Dipstick

Air
Cleaner

Vacuum
Pump Oil
Reservoir

Vacuum
Pump
Silencer

Engine
Fuel
Filter

Unit
Lifter

Engine
Stop
Lever

Engine

Valve
Cover

Suction

Vacuum
Pump

Ball
Valve

Mechanical
Seal Oil
Reservoir

Priming
Tank

Key Switch
& Hours
Recorder

Battery

6.

Daily Maintenance

1. Check fuel level and top up as needed.

2. Check Vacuum Pump oil level and top up if

needed.

3. Check Mechanical Seal oil level and top up if

needed.

4. Check Engine oil level and top up if needed.

7.

Weekly Maintenance

1. Remove the drive belt guard and check the

tension of the vacuum pump drive belt thus:

2. Check all fasteners and tighten if needed.

3. Check for damage to the lifter bracket and

replace if damaged.

4. Check battery charge and electrolyte level, top up

and charge if required.

5. Check ball valve and remove any trapped debris.







Our policy is one of continuous improvement and we reserve the
right to alter specifications at any time. For full operating and
maintenance instructions, refer to the Pump Manual.

SPP Pumps Limited, Theale Cross, Reading, Berkshire,
ENGLAND, RG31 7SP

Tel: 01189 323 123

SPP – W72-002aOIErev01- RN34041 – June06

Pump Operators Instructions

Autoprime - AC50-75 Pumps

Ref. Manual No W72-002/10


1.

Safety Instructions

2. Always lift pump sets vertically by the lifting eye.

Do not lift with the forks of a fork truck under the
fuel tank.

3. Never lift with suction or delivery hoses attached.

The increased weight of these items may cause
lifting gear failure.

4. Check the condition and security of the lifter at

regular intervals and do not lift if lifter is damaged
or loose.

5. The lift must always be vertical on the eye

provided.

6. Never allow the unit to be subject to a ‘snatch’

loading.

7. Do not allow the unit to swing whilst being lifted.

8. Ensure that all the flange bolts are used to fit the

quick release hose connections.

9. Collapsible or layflat hoses must NOT be used on

the suction side of the pump.

10. Never insert anything into the pump casing whilst

the pump is running and the suction or delivery
hoses are disconnected.

11. Moving parts are guarded to protect you. Guards

removed for maintenance must be replaced
before starting the pump.

12. Always provide adequate ventilation for diesel

engines. Be aware of fire risks from items such
as exhaust pipes and silencers. Never place
flammable items around the unit.

For further information contact: