SPP Pumps Thrustream - Extended User Manual

Page 18

Advertising
background image

Manual No/Rev

W12-005E / 3

Operators Instructions for Horizontal

Extended Thrustream Centrifugal Pumps

Our policy is one of continuous improvement and we reserve the right to alter specifications at any time

Page 16 of 28

3.

DO NOT OVERSPIN A CLEAN DRY
BEARING.

4.

Inspect the bearings for wear, fractures,
cracks, corrosion or other damage to the
running surfaces, which may necessitate
replacement.

5.

Coat the bearings with rust preventive oil and
wrap in greaseproof paper.

Note: It is recommended that all ‘V’ rings, ‘O’ rings

and gaskets: are replaced by new parts during
an overhaul. If ‘O’ rings are to be reused they
should be left in place in their grooves and
protected from contamination by oil and dirt.

6.

Remove all O-rings from their grooves and
discard where these are to be replaced.

7.

Remove all grease and other deposits from all
other parts using suitable cleaning fluid and a
clean dry cloth.

8.

Coat all unpainted carbon steel parts with a
light smear of oil to prevent rust.

9.

Measure the inside diameter of the wear rings
and the outside diameter of the wear ring
surfaces on the impeller, calculate the
clearance and compare these with dimensions
in Section 6.7.


10. Mount the shaft between point centres or on

rollers, and place the stem of a dial indicator in
contact with the shaft. Set the indicator dial at
zero and turn the shaft slowly by hand.
Readings at any point A, B, C, D and E must
not vary more than 0.05mm (0.002").

11. For soft packed pumps: examine the shaft

sleeves for wear, replace the sleeve if it is
scored or has any visible surface damage.


12. If the shaft runs true within tolerance, remount

the shaft as in 2 but with the sleeve fitted in
position, and check the sleeves run-out at the
packing contact positions. Indicator readings
must not vary more than 0.08mm (0.003").

13. The sleeve can be re-ground to provide a new

packing surface, to a maximum of 1.0mm
(0.04") below the initial diameter. Do not grind
reduce sleeve diameter in the throat bush
area unless scored. The surface finish of the
sleeve should be 20-30 C.L.A.


14. Scour any rust or scale from internal iron non-

fitting surfaces and immediately repair or
renew any previous coating. Use WRC

approved coating for pumps used for potable
water.


15. Clean all threads with kerosene followed by

wire brushing, dry and wrap shaft threads with
protective adhesive tape.


16. If the unit is not to be reassembled

immediately, brush all bright iron and steel
surfaces with Texaco Rust Proof Compound L
or Rust Proof Compound Spray or a suitable
equivalent rust preventive fluid.

17. Protect all parts (especially mechanical seal

parts and faces) against loss, weather or
mechanical damage.

6.8

Before reassembly:


1

Re-examine all old parts intended for re-fitting.
Worn, damaged or corroded parts should
either be re-conditioned or, if beyond this, be
discarded and replaced by new.


2

Ensure that all parts to be refitted (especially
new parts) are free from burrs, with screw
threads and abutting faces clean and free
from damage.


3

Examine 'O' and 'V' rings and renew if
showing wear, damage or deterioration.


Pump Reassembly

1

Lightly smear the shaft (71) with clean good
quality grease or light oil.


For clockwise rotation:

DIMN. A

IMPELLER
KEY

DRIVE END IMPELLER

NUT OR SLEEVE

For counter-clockwise rotation:

DIMN. B

IMPELLER

KEY

NON-DRIVE END IMPELLER
NUT OR SLEEVE

Note The position of the impeller key and the locked

sleeve or impeller nut is governed by the
direction of rotation of the pump. For
clockwise pumps they are fitted at the drive
end of the shaft slot and for counter-clockwise
pumps they are at the non-drive end.

Advertising