LED

DESCRIPTIONS

ON: The heaters are on
FLASHING: The working setpoint is being changed
OFF: The heaters are off

ON: The blower motor is ON
OFF: The blower motor is OFF

ON: Light switched on manually
FLASHING: Normal mode. Light switched on because
of door opening.
OFF: The light is off

ON: Alarm or error in progress

ON: The temperature scale will be in degrees Fahrenheit

ON: The temperature scale will be in degrees Celsius

ON: The instrument is in stand-by mode

ALARM CODES, DESCRIPTIONS & RESOLUTION(S)

Code

Type of Alarm

AL

Minimum Temperature Alarm

RESOLUTION:
(a) Verify cabinet temperature
(b) The alarm will activate when the temperature is 20°F below the
setpoint temperature for 30 minutes

AH

Maximum Temperature Alarm

RESOLUTION:
(a) Verify cabinet temperature
(b) The alarm will activate when the temperature is 20°F above the
setpoint temperature for 30 minutes

id

Door Ajar Alarm

RESOLUTION:
(a) Make sure door is closed
(b) Verify operation of magnetic door switch

ERROR CODES

Code

Type of Alarm

Pr1

Cabinet Sensor Error

RESOLUTION:
The cabinet sensor is located inside the cabinet at the top.
(a) Verify the integrity of the sensor.
(b) Verify the control sensor connection.

*Note: When this error occurs, the control will go into a safe mode.
The unit will operate in a pre-programmed ON/OFF cycle.

KEYPAD BUTTONS

*Note: Use

"V-TEMP™ Keypad" illustration above to follow these instructions.

Button 1: ON/STANDBY
Press this button for a few seconds to switch the cabinet on and off.

Button 2: AUX
Reserved button

Button 3: CABINET LIGHT
This button is used for the glass door option. Press this button to
switch the light on and off manually.

Button 4: DOWN BUTTON
This button is used in conjunction with the SET button to decrease
the setpoint.

Button 5: UP BUTTON
This button is used in conjunction with the SET button to increase
the setpoint.

Button 6: SETPOINT
This provides access to the set point edit function.

KEYPAD FUNCTIONS

*Note: Use

"V-TEMP™ Keypad" illustration above to follow these instructions.

KEYPAD LOCKING & UNLOCKING (*Manager's Lockout Feature)

a. The keypad is locked by pressing (1) “ON” and (4) “DOWN”
buttons simultaneously. The display will show the message
“Loc” for 1 second.

b. The keypad is unlocked by pressing (1) “ON” and (4) “DOWN”
buttons simultaneously. The display will show the message
“UnL” for 1 second.

SILENCING BEEPER (or AUDIBLE ALARM)

When the beeper is active, press any button to silence the alarm.

SETTING TEMPERATURE SETPOINT

a. Press the (6) “SET” button: the snow flake LED will flash and
display will show the current SETPOINT.

b. Press the (4) “DOWN” or (5) “UP” button within 15 seconds.

c.

Press the (6) “SET” button to complete procedure. The

snow flake LED will switch off.

*Note: Set point is the cut out temp. A warmer has a 4˚F differential;
When a warmer is set at 160˚F, it will cycle between 156˚F and
160˚F.