Wiring, Wiring guidelines, Preparing/connecting captive wires – AMX AXB-TCR User Manual

Page 11: Tv sensor connections

Advertising
background image

Installation and Wiring

7

AXB-TC and AXB-TCR Television Controllers (& Receivers)

Wiring

The TV sensor, IR emitter, AXlink, and 12 VDC power supply connectors are located on the rear panel
of the television controller as shown in FIG. 1 on page 1.

Wiring guidelines

The television controller requires 12 VDC power to operate properly. The power can be supplied via
AXlink cable, or with an optional 12 VDC power supply. The maximum wiring distance between the
Central Controller and television controller is determined by power consumption, supplied voltage, and
the wire gauge used for the cable.

The following table lists wire sizes and the maximum lengths allowable between the television controller
and Central Controller. The maximum wiring lengths are based on a minimum of
13.5 volts available at the Central Controller's power supply. If a television controller is installed farther
away from the Central Controller than recommended in the table, connect a 12 VDC power supply to the
2-pin 12 VDC PWR connector on the rear panel.

Preparing/connecting captive wires

1.

Strip 0.25 inch of wire insulation off all wires.

2.

Insert each wire into the appropriate opening on the connector according to the wiring diagrams and
connector types described in this section.

Do not tighten the screws excessively; doing so may strip the threads and damage the connector.

TV Sensor connections

Connect the CC-IR to the TV Sensor connector, on the rear panel of the television controller, as shown in
FIG. 2 to detect horizontal scan frequencies up to 65 kHz.

Do not connect power directly to the television controller. If you are using power from
AXlink, disconnect the wiring from the Central Controller before connecting the wiring
to the television controller. If you are using an optional 12 VDC power supply, apply
power to the television controller only when installation is complete.

Wiring Guidelines - TC - 175 mA

Wiring Guidelines - TCR - 200 mA

Wire size

Maximum wiring

length

Wire size

Maximum wiring

length

18 AWG

670.69 feet (204.43 meters)

18 AWG

586.55 feet (178.78 meters)

20 AWG

424.33 feet (129.34 meters)

20 AWG

371.29 feet (113.17 meters)

22 AWG

264.55 feet (80.63 meters)

22 AWG

231.48 feet (70.56 meters)

24 AWG

166.76 feet (50.83 meters)

24 AWG

145.91 feet (44.47 meters)

FIG. 2

CC-IR TV Sensor connector wiring diagram

TV SENSOR

connector

GND

SEN

CC-IR

Television

Advertising