Disarming diagnostics, System status chirps – Avital 3300L User Manual

Page 32

Advertising
background image

27

© 2 0 0 8 d i r e c t e d e l e c t r o n i c s — a l l r i g h t s r e s e r v e d

disarming diagnostics

Extra chirps that are heard when disarming the system are the

Tamper Alert. If four chirps are heard when disarming the

system, then the security system was triggered in your absence. If

five chirps are heard when disarming the system, a zone was trig-

gered so many times that the Nuisance Protection

®

Circuitry has

bypassed that zone. In either case, the status LED will indicate

which zone was involved (see Table of Zones section). The secu-

rity system will retain this information in its memory and chirp

four or five times each time it is disarmed, until the next time

that the ignition is turned on.

system status chirps

The siren will chirp when arming/disarming the system. The

pattern of chirps will audibly report the system’s status as

described below.

Action

Number of Chirps

Description

Arm

1

System armed

Arm

1 (3-second delay), 1

System armed with
Bypass Notification

Disarm

2

System disarmed

Disarm

4

System disarmed with
Tamper Alert

Disarm

5

System disarmed NPC

®

active

Advertising