DSP1500 SAN Unit Operation Manual

PAGE 6-21 (Rev

4)

Chapter 6: System Operation

¾

Data Number

30

Home Position Search Time Out [0 ~ 999.9 sec.]

It sets the time limit of the home position search operation. The default setting is 120.0.
*If the operation has not finished within the time limit an abnormal will occur and the
Reject light will flash.

¾

Data number

31

Home Position Search Speed [Tool minimum speed ~ 10mm/sec.]

This data field sets the speed of the Home Position Search operation.
* The maximum speed of the Home Position Search operation is 10mm/sec. If the value
set is higher than 10mm/sec., the speed will be limited to 10mm/sec.

¾

Data Number

32

Manual Operation Speed [Tool minimum speed ~ maximum speed]

This data field sets the speed of MANUAL operations. The manual Jog operating speed
and the speed of the Home Return operation will be set to this value.

¾

Data Number

33

Stroke Distance Limit [0 ~ 999]

This data field sets the maximum stroke the press will be allowed. If set to zero, the
distance is unlimited. The default setting is zero.
* If setting Distance High Limit Stop [00-37] to “1” a Stroke Distance Limit must be set. If
set to zero Distance High Limit Stop will be disabled.

¾

Data Number

34

Approach Distance Limit [0 ~ 999]

This data field sets the distance limit that the press can run at Approach Speed. If set to
zero, the distance is unlimited. The default setting is zero.

¾

Data Number

35

Home Returned Signal Output Range [0 ~ 999]

The Home Returned signal will be output when the press stops within +1mm of the value
set.
(Ex: If 10 is set, the Home Returned signal will be output if the press stops between 0
and 11mm)
The default setting is zero.

¾

Data number

36

Load Cell / Dynamic Hold / Home Sensor / RS232&485 Comm. Speed


□ □ □ □

0: Load Cell [Yes] (Default)

1: Load Cell [No]


0: Dynamic Hold [On] (Default)

1: Dynamic Hold [Off]

Dynamic Hold should be set to 0 [ON] unless
instructed by FEC. This allows the servo motor to
hold the press ram when the operation has stopped.
If Dynamic Hold option is set to 1 [OFF], system will
automatically be set to SERVO OFF mode after the
operation has finished.


0: Home Position Sensor [No] (Default)

1: Home Position Sensor [Yes] (Option on larger presses)

*0: RS-485

9600bps RS-232C

9600bps

*1:

19200bps 9600bps

2: 38400bps 9600bps

*3: 9600bps 19200bps

*4:

19200bps 19200bps

5:

38400bps 19200bps

*6:

9600bps 38400bps

*7:

19200bps 38400bps

8:

38400bps 38400bps

Power must be cycled for these changes to take effect.

*Available only when configured for Stand Alone




Н