32

Fault

Possible cause

Remedial action

The refrigerating unit
is switching on more
frequently and for
longer.

Appliance opened
frequently.

Do not open the appliance
unnecessarily.

The ventilation
openings have been
covered.

Remove obstacles.

Appliance has no
refrigeration capacity.
The light does not
work.
The display does not
illuminate.

Appliance has been
switched off.

Press the On/Off button.

Power failure.

Check whether the power is on.

The fuse has been
switched off.

Check the fuse.

The mains plug has
not been inserted
properly.

Check whether the mains plug is
secure.

Appliance is not
cooling, temperature
display and light
are lit.

Showroom mode is
switched on.

Hold down alarm button, Fig 2/1,
for 10 seconds until an acknowl-
edgement signal sounds.
After a short time check whether
your appliance is cooling.

The light does not
function.

The LED light
is defective.

See chapter “Light (LED)” section.

Appliance was open
too long.
Light is switched off
after approx. 10 min.

When the appliance is closed
and opened, the light is on again.

Temperature display
refrigerator
compartment is
flashing. Fig. 2/4

Appliance opened
frequently.

Do not open the appliance
unnecessarily.

Too much food was
placed in the
compartment.

Before placing food in the freezer,
press the “super” button.

The ventilation
openings have been
covered.

Remove obstacles.

Advertising