Fault, Possible cause, Remedial action – Bosch GSN36BW30 Congelatore verticale Bianco User Manual

Page 34: Warning signal sounds, alarm display lights up, Appliance is open, Close the appliance, Ventilation openings have been covered, Ensure that there is adequate ventilation, Do not exceed max. freezing capacity, Showroom mode is switched on

Advertising
background image

en

34

Fault

Possible cause

Remedial action

Warning signal
sounds, Alarm display
lights up.
The freezer
compartment is too
warm! Frozen food
is at risk!

To switch off the warning signal,
press the Alarm button. Fig. 2/7

Appliance is open.

Close the appliance.

Ventilation openings
have been covered.

Ensure that there is adequate
ventilation.

Too much food was
placed in the freezer
compartment at once.

Do not exceed max. freezing
capacity.

When the fault has been eliminated,
the Alarm display goes out shortly
afterwards.

Freezer compartment
door was open
for a long time;
temperature is no
longer reached.

The evaporator
(refrigeration
generator)
in the No Frost system
is covered in thick ice
and can no
longer be defrosted
fully automatically.

To defrost the evaporator, remove
the frozen food
with the compartments, insulate well
and store in a cool location.
Switch off the appliance and move
it away from the wall. Leave
the appliance door open.
After approx. 20 min.
the condensation begins to run
into the evaporation pan,
at the rear of the appliance. Fig. *
To prevent the evaporation pan
from overflowing in this case,
mop up the condensation
with a sponge.
The evaporator is defrosted when
the water stops running
into the evaporation pan. Clean
the interior. Switch the appliance
back on again.

Appliance is not
cooling, temperature
display and light
are lit.

Showroom mode is
switched on.

Hold down alarm button, Fig 2/7,
for 10 seconds until
an acknowledgement signal sounds.
After a short time check whether
your appliance is cooling.

Advertising