4 3.2.4 jumper setting description, Jumper setting description – Advantech 4718 User Manual

Page 33

Advertising
background image

27

Chapter 3

3.2.4 3.2.4 Jumper Setting Description

JP1~JP8: Input Mode Setting for Analog Input Channels
The analog input mode of every AI channel on USB-4718 can be set by
JP1~JP8 separately to measure the voltage sources or the current sources.
Inappropriate setting of the jumpers can cause unpredictable errors or
malfunction of USB-4718.

Table 3.3: Jumper Setting Description

Jumper

Description

Jumper Description

JP1

Input mode set-
ting for analog
input ch0

JP6

Input mode setting for analog
input ch6

JP2

Input mode set-
ting for analog
input ch4

JP7

Input mode setting for analog
input ch3

JP3

Input mode set-
ting for analog
input ch1

JP8

Input mode setting for analog
input ch7

JP4

Input mode set-
ting for analog
input ch5

JP13

Watchdog timer setting

JP5

Input mode set-
ting for analog
input ch2

Jumper
Setting

Description

Set the channel to voltage
input mode (Default setting)

Set the channel to
current input mode