Aqua Products Auto-Chlor AC-6000 User Manual

Page 9

Advertising
background image

9

220Volt Circulation Pump With 220 Volt Chlorine Generator


120Volt Circulation Pump With 240 Volt Chlorine Generator

A 240 Volt Chlorine Generator may NOT be connected to a system with a 120 Volt circulation pump.


W i r i n g t h e C e l l

Connect the two black wires from the Control Box to the two metal studs on the sides of the Cell and tighten
firmly with a screwdriver by hand. To avoid damage to the screws, DO NOT use a power screwdriver. Note
these wires are interchangeable. Push the plastic terminal covers up to cover the terminal connection until
they click into place. This will ensure a watertight connection.















W i r i n g t h e F l o w S e n s o r

Find the two 18 AWG wires with the ¼” Quick connect terminals from the Cell cable and push them on their
respective connectors on the Flow Sensor. These wires are interchangeable.