Trouble shooting guide – Blagdon Pump X50 High Pressure User Manual

Page 7

Advertising
background image

HG-CF-1087 Rev. I – 01.05.13

PAGE 7

TROUBLE SHOOTING GUIDE

NOTE :- Check all solutions before dismantling the pump.

PROBLEM

CAUSE

SOLUTION

Pump will not start

Air valve assembly malfunction/Siezure

Obstructed fluid line.
Obstructed diaphragm chamber.
Diaphragm failure causing fluid & excessive air to be
expelled through the exhaust.
Diaphragm seal failure.
Air valve system malfunction.
Air connected to exhaust.

Check carrier for freedom of movement. -
Clean, oil & replace.
Clean line or increase line size.
Remove obstruction.
Replace diaphragm.

Replace shaft seals.
Check all seals in valve chest assembly.
Re-connect to air inlet.

Erratic flow

Diaphragm failure on one side.
Valve ball not seating.
Suction leakage.
Diaphragm failure causing fluid & excessive air to be
expelled through the exhaust.
Diaphragm seal failure.
Air valve system malfunction.

Replace diaphragm.
Check and remove obstruction.
Check and correct.
Replace diaphragm.

Replace shaft seals.
Check all seals in valve chest assembly.

Pump strokes but will not
discharge

Excessive suction lift.
Suction line leakage.
Valve ball not seating correctly or damaged.
Suction line or strainer clogged.
Diaphragm failure.

Shorten suction line.
Check and correct.
Check and remove obstruction / replace.
Clear.
Replace diaphragm.

Fluid discharged from air
exhaust

Diaphragm Failure.
Loose frontplate.

Replace diaphragm.
Re-Torque to manual specifications.

Intermittent stroke rate

Over lubrication



Diaphragm shaft seal failure.
Air valve system malfunction.
Valve ball not seating / partially obstructed.

Shut-down pump. Remove air connection
into pump & introduce a small quantity of de-
greasing agent into air valve and replace
line. Run pump until clear.
Replace seals.
Check all seals in valve chest assembly.
Clear obstruction.

The Atex approved units are supplied with a natural earth ground
cable. This cable is 2 meters in length and permanently connected
through a nut and bolt at the inner cover casting. The other end is free
to connect to the nearest available suitable point to provide a natural
earth ground. This must be done to reduce the risk of electro-static
sparking.

Grounding the pump :-


Take action to prevent static sparking. Fire or
explosion can result, especially when handling
flammable liquids. The pump, piping, valves,
containers or other miscellaneous equipment
must be grounded.

WARNING!

ATEX Certified units :- X5005SA..

These models are certified to :-


Non-electrical equipment for potentially explosive atmospheres,
: EN13463-1 : 2001, ‘c’ - Internal control of production.

II 2 GD c

Refer to table on page 10 for key to balloon references.

Advertising
This manual is related to the following products: