Hf series, General pump – General Pump HF Repair Manual User Manual

Page 8

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

HF SERIES

Page 8

The shim pack must be reassembled as follows:

A)

Insert the crankshaft in the crankcase, being sure that the P.T.O. shank comes out of the

correct side.

B)

Fit the P.T.O. side flange to the crankcase paying close attention to the seal lip as indicated in

paragraph 2.1.2, section C.

C)

Position the flange on the sight glass side as indicated in paragraph 2.1.2.

D)

Use a thickness gauge (see fig. 10).

Determine the shim pack as indicated in the table below:

E)

Insert the shims under the cover on the sight glass side (see fig. 11), fixing it to the crankcase

using the appropriate screws, and verifying that the stall torque is between 3-5 Ft. Lbs.

( 4-7 Nm).

F)

If the torque value is correct, connect the rods to the crankshaft; otherwise, reposition the

shims again repeating the operations from point C.

Measurement

Shim

Type

No. of

Pieces

From: 0.05 to 0.10

-

-

From: 0.11 to 0.20

0.1

1

From: 0.21 to 0.30

0.1

2

From: 0.31 to 0.35

0.25

1

From: 0.36 to 0.45

0.35

1

From: 0.46 to 0.55

0.35

0.10

1

1

From: 0.56 to 0.60

0.25

2

From 0.61 to 0.70

0.35

0.25

1

1

Ref 300623 Rev.A

01-12

Advertising