9.7 Internal diameter of piping

To determine the internal diameter of the piping, follow the following diagram.

Example 1 (-----)

With a flow of 150 l/m and a water speed of 0.45 m/sec, the diagram line joining the 2 scales intersects the central

scale, indicating the diameters, at a value of 80mm.

Example 2 ( )

With a flow of 70 l/min and a water speed of 5.5 m/sec, the diagram line joining the 2 scales intersects the central

scale, indicating the diameters, at a value of 16mm.

Optimal speeds:

- suction:0.5 m/sec

- delivery: 5 m/sec

The diagram does not take into consideration the pipe and valve resistance, drop in pressure, due to the

pipe length, the viscosity of the pumped fluid, its temperature, etc.