4. PUMP IDENTIFICATION

Each pump is fitted with a rating plate (see Fig. 1)

containing the following information:

2. pump model and version

3. serial number

4. max RPM

5. max operating pressure (bar)

6. oil capacity (ltr) and oil specification

7. max flow rate (l/min)

Pump model, pump version and serial number should

be specified when ordering spare parts. Should the pump

be modified (i.e by changing the original version) than

any change should be mentioned on the rating plate for

future reference.

5. TECHNICAL FEATURES

6. DIMENSIONS AND WEIGHT

MODEL

RPM

FLOW RATE

PRESSURE

POWER

GPM

l/min

PSI

Bar

Hp

kW

KL30

1000

22.2

84

2600

500

39.6

29.1

KL33

1000

27.0

102

2150

400

39.8

29.2

KL36

1000

32.2

122

1750

320

37.4

27.5

KL40

850

33.8

128

1600

250

36.6

26.9

KL45

800

40.1

152

1450

180

39.6

29.1

KL50

700

43.3

164

1150

34.0

25.0