9.5 Filtration

All pumps require a suitable filter. The filter should be

installed as close as possible to the pump, should allow

easy inspection and have the following characteristics:

1. The filter capacity should be at least three times the

rated pump volume.

2. Filter port diameters should not be smaller than the

pump inlet ports.

3. Filtration degree in between 50 and 80 mesh (360

to 200 microns.

IMPORTANT NOTE: In order to properly safeguard the

pump it is very important to plan cleaning of the filter

with a frequency depending on the water quality,

filtration degree and number of hours of each

application.

9.6 Delivery line

For a correct delivery line comply with the following

instructions:

1. The first length of delivery hose should be flexible in

order to isolate the pump vibrations from the

rest of the system.

2. Use only high pressure hoses and fittings able to

guarantee the largest possible safety margins in

any working conditions.

3. A suitable relief valve should be installed in the

delivery line.

4. Use glycerine filled pressure gauges, as the most

suitable for pulsating loads.

5. When designing the delivery line, take into proper

account the unavoidable drop in pressure, due to

its length and size.

6. If necessary, the effects of the pump pulsations

can be reduced by installing a proper pulsation

dampener in the pressure line.