11.3 Pumping unit maintenance

The only maintenance operation required for the pumping

unit is the pressure packings greasing through the proper

greasers (1, Fig. 16).

Greasing should be carried out at even intervals

at least every 100 hours by means of a hand pump.

Stop greasing when the pump trigger becomes harder

to operate: that means the grease chamber is full. Use

top quality silicone grease (i.e. DANKELL OCILIS 250,

penetration coefficient 290 or a corresponding one).

Periodically check the amount of water drained out by

the pump through the hole provided in the lower cover

(Fig. 7, page 9). It clearly shows the pressure packing

state of wear; replace them if water dripping becomes

continuous and not intermittent.

For inspecting the pumping unit remove the head by

loosening the eight head screws (1, Fig 17).

Loosen and remove the plunger screws (1, Fig. 18).

Remove the upper cover by loosening the four screws

(1, Fig. 19).

Push the plungers forward by rotating the crankshaft,

then introduce our tool pn/ F200030060 (or equivalent)

in between the piston guide and the packing support

(1, Fig. 20).

Advertising