General Pump TX-63 Series User Manual

Tx series “63, Servicing instructions, General pump

Advertising
background image

TX Series “63”

GENERAL PUMP

A member of the Interpump Group

TR

IP

LE

X

TR

IP

LE

X

Triplex Plunger Pump

SERVICING INSTRUCTIONS

SERVICING PUMP PROCEDURES

General Pump

is a member of

the Interpump Group

8

Valve Replacement: All inlet and discharge valves can be serviced without disrupting the inlet or discharge

plumbing. The inlet and discharge valves are identical in all 63 series models.

To service any valve:

1) Remove valve cap and examine o-ring. Replace o-ring if there is any

evidence of cuts, abrasions, distortion or wear.

2) Remove valve assembly (retainer, spring, valve, valve seat) from

valve cavity.

3) Remove valve seat o-ring from valve cavity.

4) Inspect manifold for wear or damage.

5) Install new o-ring in valve cavity.

6) Insert valve assembly into valve cavity.

7) Replace valve cap and torque to specification.

NOTE: Only one valve kit is necessary to repair all the valves

in the pump. The kit includes new o-rings, valve seat, poppet, spring and

retainer. All are pre-assembled.

Ref 300685 Rev. B