At every valve inspection, always replace all seal rings and relative o-rings between the

liner and head, between the head and liner spacer in the recirculation inlet area. Clean and

dry components and all relative housings inside the head before replacing.

Extract the outlet plates (1, fig. 105) and their respective guides (1, fig. 107) with their springs (1, fig. 106).

Check their conditions, replace if necessary and at the intervals necessary as indicated in Chapter 11 of the

Owner’s Manual.

Extract the valve housings and check the conditions of the various components. If necessary, make any

replacements (1, fig. 104).