General Tools and Instruments DAF80PW User Manual

Page 7

Advertising
background image

4. MEASURING PROCEDURE

4-1 Air velocity/Temperature measurement

1 )Install the " Probe Plug " ( 3-13, Fig. 1 ) into the

" Input Socket " ( 3-8, Fig. 1 ).

2) Power ON the meter by pressing the " Power Button "

( 3-2, fig. 1 ).

3) a. Select the desired air velocity unit ( m/s, km/h, mph,

knots, ft/min ) by pusing the " unit Button " ( 3-5, fig. 1 ).

b. Select the desired temperature units by pusing the " 蚓/蚌

Button " ( 3-6, fig. 1 ).

4) Use the hand to hold the " Probe Handle " ( 3-12, Fig. 1 ),

face the " Vane Probe Head " ( 3-11, Fig. 1 ) to the

measured wind. In the same time the air velocity and the
temp. value will show on the LCD display.

Measuring Consideration :

The yellow dot mark on the sensor head indicates the

" yellow dot mark " need to face against the direction of

air flow.

4-2 Data Hold, Date Record

1) Data Hold

a. During the measurement, pushing the " Data Hold

Button " ( 3-3, Fig. 1 ) will hold the measured value &

the LCD will indicate " HOLD " symbol.

b. Push the " Data Hold Button " again to release the

data hold function.

2) Data Record ( Max., Min. reading )

a. The data record function records the maximum and

minimum readings. Press the " REC. Button " ( 3-4,

Fig. 1 ) to start the Data Record function and there

will be a " REC " symbol on the display.

5