background image

MANTEL LOCATION

When choosing a location for your new fireplace,

ensure that the general instructions are followed.

Also, for best effect, install the fireplace out of

direct sunlight.

Cold climate installation recommendation:

when installing this unit against a

non-insulated exterior wall or chase, it is

mandatory that the outer walls be insulated

to conform to applicable insulation codes.

ELECTRICAL CONNECTION

A 15 AMP, 120 Volt, 60 Hz circuit with a

properly grounded outlet is required. Preferably, the

fireplace will be on a dedicated circuit as other

appliances on the same circuit may cause the circuit

breaker to trip or the fuse to blow when the heater is

in operation. The unit comes standard with 6 feet

(1.8 m) three wire cord, exiting from the rear of the

fireplace. Plan the installation to avoid the use of

an extension cord. If an extension cord must be

used, it must be a minimum 14 AWG , three wires

ELECTRICAL SPECIFICATIONS

Voltage: 120 V~, 60Hz

Amps: 12.5 Amps (with heater)

Amps: < 0.1 Amps (without heater)

Watts: 1500 Watts (with heater)

Watts: < 10 Watts (without heater)

CLEARANCE TO COMBUSTIBLES

Keep electrical cords, drapery, furniture and other

combustibles at least 3 feet (0.9 m) from the front of the

heater and away from the sides.

CLEANING TRIM

Clean the metal trim using a soft cloth, slightly

dampened with citrus oil based product and buff with

a clean soft cloth. DO NOT use brass polish or

household cleaners as these products will damage

the metal trim. Citrus oil based products can be

obtained at supermarkets or hardware stores.

MAINTENANCE

The motors used on the fan and the flame generator assembly are pre-lubricated for extended bearing life and

require no further lubrication. However, periodic cleaning/vacuuming of the fan/heater unit is recommended.

Make sure the unit is turned OFF and unplugged whenever you are cleaning the heater or fireplace.

WARNING: Make sure the power is turned off before proceeding. Any electrical repairs or

rewiring of this unit should be carried out by a licensed electrician in accordance with

national and local codes.

If repairing or replacing any electrical component or wiring, the original wire routing, color

coding and securing locations must be followed.

WARNING: Electrical outlet wiring must comply with local building codes and other applicable

regulations to reduce the risk of fire, electrical shock and injury to persons.

WARNING: Do not use this fireplace if any part of it has been under water. Immediately call a

qualified service technician to inspect the fireplace and replace any part of the electrical system.

Warning: Disconnect power before attempting any maintenance or cleaning to reduce the risk

of fire, electrical shock or personal injury.

MAINTENANCE

The motors used on the fan and the flame generator assembly are pre-lubricated for extended bearing life and

require no further lubrication. However, periodic cleaning/vacuuming of the fan/heater unit is recommended.

Make sure the unit is turned OFF and unplugged whenever you are cleaning the heater or fireplace.

WARNING: Make sure the power is turned off before proceeding. Any electrical repairs or

rewiring of this unit should be carried out by a licensed electrician in accordance with

national and local codes.

If repairing or replacing any electrical component or wiring, the original wire routing, color

coding and securing locations must be followed.

WARNING: Electrical outlet wiring must comply with local building codes and other applicable

regulations to reduce the risk of fire, electrical shock and injury to persons.

WARNING: Do not use this fireplace if any part of it has been under water. Immediately call a

qualified service technician to inspect the fireplace and replace any part of the electrical system.

Warning: Disconnect power before attempting any maintenance or cleaning to reduce the risk

of fire, electrical shock or personal injury.

TROUBLE SHOOTING GUIDE

Warning: During any service of this appliance, the power to the unit must be turned off.

First turn the main power switch to the “OFF” position. Then remove the electrical plug from

the wall outlet.

with grounding type plug connector and rated

not less than 1875 Watts. The cord shall not be

more than 20 feet (6 m) in length.