Kasco Marine Quick Disconnect User Manual

Assembly instructions for quick disconnect

Advertising
background image

Assembly Instructions for Quick Disconnect


Kasco Marine Part # 636220 – Quick Disconnect for 12 gauge cords
Kasco Marine Part # 636224 – Quick Disconnect for 10 gauge cords

Important – Read Carefully Before Installation

Before using the connector, it is important that these instructions are carefully read and understood to
ensure the connector system is completely water tight and electrically safe.
IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN.

The socket (female) insert of the connector must be the live part of the connector from the supply. The pin
(male) insert of the connector must lead to the load or electrical device. To ensure efficient sealing, use
only smooth circular cable.
______________________________________________________________________________________

Figure 1: Pin Insert

Note:
Grey gland for 14 gauge


_____________________________________________________________________________________

Gland Nut

Main Body

Pin insert

Gland



Figure 2: Socket Insert

Note:
White gland for 12 gauge
Yellow gland for 10 gauge


______________________________________________________________________________________

Gland Nut

Main Body

Socket insert

Gland

Assembly/Wiring Instructions

Step 1: Remove the pin or socket insert from the housing of the connector. There is a slot for a flat blade
screwdriver in the center of the insert.
Note: The inserts have a LEFT HAND THREAD and should be turned clockwise to remove.

Step 2: Remove the gland nut and gland from the rear of the housing and slide on to the cable. Make sure
the gland is orientated with the stepped edge facing the nut (see Figure 3).

Figure 3: Wire Assembled

Stepped Edge

(continued)

Advertising