The charger will automatically restart the charging cycle in Bulk stage if the battery is discharged
to 12.5V. Also, after seven days, the charger will automatically restart the recharging cycle to
refresh the battery.

Understanding the Battery Temperature Functions:

Optional Battery Temperature Sensor KISAE Part Number #BTS-10K is highly recommended
with the charger to protect your battery and provide better charging voltage accuracy. The
battery temperature sensor senses the battery temperature and makes small adjustments to the
charging voltage. If the battery sensor is not in use or not available, you can manually set the
battery temperature. There are three manual battery temperature settings on the unit. The
battery temperature sensor will override the manual setting when the sensor is used. See below
for voltage adjustments for temperature compensation.

Temperature

Setting

Recommended for

Battery

Temperature

Battery Type

Voltage adjustment

from 25°C normal

setting

GEL, Flooded

0.675 V

Low (Lo)

<5°C

(41°F)

AGM 0.525

V

GEL, Flooded

0 V

Normal (nor)

>5°C and <30°C

(>41°F and <86°F)

AGM 0

V

GEL, Flooded

-0.27 V

High (HI)

>30°C
(86°F)

AGM -0.21

V


Procedure to set or view charger setting:

Follow the procedure or sequence in Appendix A to set or view the charger setting.
GEL, AGM or Flooded battery type:

Parameters below are required for setting:

• Battery type (GEL, AGM, Flooded)
• Charging stage (3-stage , 2-stage)

• Battery temperature (low, normal, high temperature)

• Maximum Current setting (see table below)
• Absorption to float mode current setting (see table below)

The following table shows the maximum available charging current and its related available
Absorption to Float Mode current.

Model Maximum

Current

Setting

Absorption to Float

Mode Current Setting

* 20A

* 1A / 2A / 4A

15A

0.75A / 1.5A / 3A

10A

0.5A / 1A / 2A

AC 1220

5A

0.3A / 0.5A / 1A

* 40A

* 2A / 4A / 8A

20A

1A / 2A / 4A

10A

0.5A / 1A / 2A

AC 1240

5A

0.3A / 0.5A / 1A

* 60A

* 3A / 6A / 12A

40A

2A / 4A / 8A

20A

1A / 2A / 4A

AC 1260

5A

0.3A / 0.5A / 1A

Note: * Recommended setting (Factory Default Setting)

Lithium battery type:

Parameters below are required for setting:

• Charging Voltage (14.2V, 14.3V, 14.4V)
• Maximum Charging Current (see table below)

• Termination Charging Current (current to define when the charging process will terminate)

The following table shows the available charging voltage, maximum charging current, and the
available termination charging current.