LOCKSTATE LS-19EPL User Manual

Operating instruction for the lockstate ls-35epl

Advertising
background image

www.LockState.com

OPERATING INSTRUCTION for the LockState LS-35EPL

CAUTION: Do not keep the keys in the safe.

Thank you for purchasing the LockState LS-35EPL hotel and laptop safe. This safe will install easily on
floors, walls or in closets. This easy quick-start guide will help you through the installation and programming
process.


1. OPENING THE SAFE THE FIRST TIME

Use a screw driver to pry off the round plastic cover situated to the right of the keypad (see “A” in diagram 1),
exposing the keyhole underneath. Insert the key into the keyhole and turn it clockwise to retract the bolts
and open the safe door. You can follow these steps to manually open your safe anytime. Note that the
motor will NOT work when the override key is in the keyhole and the safe is in the UNLOCKED status. In
this case, the LED display will read ‘Error’. To remove the override key, with the door open turn the key
counter-clockwise and take it out.

2. INSTALLING THE BATTERIES

The safe requires 4× size “AA” (1.5V) batteries. To install the batteries, open the safe, remove the battery
cover plate on the back of the door (“A” in Diagram 2) and install the batteries. Make sure the batteries are
inserted with the correct corresponding polarity. Use of alkaline batteries is recommended.


3. PROGRAMMING THE CODE

All safes are supplied with the factory preset master code ‘888888’. After inserting the batteries, you can
open the safe with this master code by entering ‘888888’ and then pressing the ‘E’ key. The door will
automatically open.


Programming a new master code

A. With the door either open or closed, press the ‘0’ key 2 times then press the ’E’ key. The display will read
‘SELECT’.
B. Now press the ‘1’ key and the display will read ‘OLD’
C. Enter the master code that was previously programmed (for new safes this code is ‘888888’) and press
the ‘E’ key. The display will read ‘SET’.
D. Enter a new Master code (a minimum of 3 digits and maximum of 6 digits) and press the “E” key. The
display will read ‘REPEAT’.
E. Again enter the new master code and press the ‘E’ key. The display will read ‘DONE’ and your new
master code is set.


Programming the user code/Locking the door

A. With the door open, enter a user code (a minimum of 3 digits and maximum of 6 digits).
B. Now push the door shut (locking bolts are still unlocked) and hold the door closed while pressing the ‘E’
key. You will hear the locking bolts lock the door automatically indicating that your new user code has been
programmed.

NOTE: While the master code remains set until it is changed using the master code change procedure, the
user code will automatically be deleted if the safe is opened even one time with the user code.


4. OPENING THE SAFE

Enter either the user code or the master code and press the ‘E’ key. The door will be automatically open.

NOTE: If 3 attempts are made to open the safe with incorrect codes, the keyboard will be disabled for 5
minutes and the display will read ‘ERROR 1/2/3’ and then ‘HOLD05’. In this case, it is still possible to open
the door with the emergency override key and doing so will nullify the 5 minute waiting period and reset the
safe to immediately accept keypad codes.