Trinity 12 analog specifications – LumaStream Trinity 12 Analog User Manual

Page 2

Advertising
background image

Trinity 12 Analog Specifications

Input

Output

System Protection

Safety and EMI/EMC

Environmental

Control Interface

Rated Input Voltage

115 to 277 Vac hard wired ; 115 to 125 Vac power cord

Rated Input Frequency

47 - 63 Hz

Power Factor EN61000-3-2

@ 115 Vac, 100% load, 0.97 W/VA min

Input Current Total Harmonic Distortion @ 115 Vac, 100% load, 13% max

Rated Output Power

@ 40°C / 104°F ambient, 243 W max

Output Voltage

66 series: 6 to 27 Vdc; 70 series: 12 to 47 Vdc

Efficiency

87% with 100% load @ 115 Vac input

System Power Cycle Delay

2 second typical time required for stabilization of all outputs

Output Current Tolerance

+/-5 % of nominal

Output

Over voltage, over current, short circuit protection

Over Temperature

Power supply will shut down when external ambient temperature
exceeds 43°C/ 109.4°F or case temperature reaches 85°C/ 185°F
nominal.

Output Interconnection

Hiccup mode with automatic recovery upon removal of short. Only
applies to +ve to -ve interconnections.

Agency Approvals

UL 8750 Class 2 outputs

Conducted and Radiated Emissions

ICES-003; FCC Title 47, Part 15, Class A (for commercial use only)

EN61000-3-2

Harmonics Emissions, Class C

EN61000-4-4

Electrical Fast Transient, 1KV Criteria B

EN61000-4-5

Surge, 2KV Criteria B

EN61000-4-11

Voltage Dips, Interruptions, and Voltage Variations, according to
EN61547

Location Rating

Dry

Operating Ambient Temperature

-20°C to 40°C / -4°F to 104°F

Cold Start Temperature

-20°C / -4°F

Storage Ambient Temperature

-40°C to 80°C / -40°F to 176°F

Relative Humidity

5% to 95% noncondensing

Mean Time Between Failure
(MIL HDBK-217F); (12 channel)

>60,000 hours @ 40°C / 104°F; >97,000 hours @ 25°C / 77°F

Control Method

Analog 0-10 Vdc, IEC 60929 Annex E Outputs 0.5 mA max or variable
0-10 Vdc Voltage Source; Class 2 outputs.

Control Zones

Master control: simultaneous control of all the output channels.
Zonal control: up to 12 independently configurable output channels.

Loss of Analog Input Signal

Outputs will go to 0% or 100% light intensity in less than 1 second; must
set default valve, 0% or 100%

LSPS08 / Trinity 12 Analog 12 Zone

© 2014 LumaStream

www.lumastream.com

+1 (727) 827-2805

Advertising