Thea 56 specifications – LumaStream THEA 56 User Manual

Page 2

Advertising
background image

THEA 56 Specifications

Input

Output

System Protection

Safety and EMI/EMC

Environmental

Control Interface

Rated Input Voltage

120 to 277 Vac

Rated Input Frequency

50/60 Hz

Power Factor EN61000-3-2

@120 Vac or 277 Vac 0.95 W/VA; 100% load

Input Current Total Harmonic Distortion @120 or 277 Vac 17% max, 100% load

Rated Output Power

58.8 W max

Efficiency

@240 Vac (no load on auxiliary output) 88% full load

System Power Cycle Delay

0.6 second typical

Output Current Tolerance

+/-5 % of nominal

Auxiliary Voltage

5 Vdc @ 400 mA, 12 Vdc @ 164 mA; less than 1% load/line regulation

Output

Over voltage, over current, short circuit protection

Over Temperature

Power supply will throttle back output current gradually when case
temperature reaches 80°C/176°F nominal.

Agency Approvals

UL 8750 Class 2 outputs, LVD EN61347-2-13, EN61347-1

Emissions

FCC Title 47, Part 15, EN55015; EN55022, Class B

Immunity

EN61547, EN55024

EMC

EN61000-3-2 (Class C); EN61000-3-3

Location Rating

IP50 Dry/Damp Location

Operating Ambient Temperature

-20°C to 55°C / -4°F to 131°F

Maximum Case Temperature

T

c

=75°C / 167°F

Storage Ambient Temperature

-40°C to 80°C/ -40°F to 176°F

Relative Humidity

5% to 95% noncondensing

Mean Time Between Failure
(MIL HDBK-217F)

>200,000 hours @ 65°C / 149°F

Control Method

Analog 0-10 Vdc, IEC 60929 Outputs 0.5 mA max or variable 0-10 Vdc
Voltage Source; Class 2 outputs.

Loss of Analog Input Signal

Outputs will go to 100% light intensity in less than 1 second

LSPS05 / THEA 56

© 2014 LumaStream

www.lumastream.com

+1 (727) 827-2805

Advertising