Needle shaft removal / replacement, Ransburg, Vector solo waterborne applicators - maintenance – Ransburg Vector Solo 79901 Waterborne RS90-WB User Manual

Page 38: Needle shaft rebuild

Advertising
background image

Vector Solo Waterborne Applicators - Maintenance

34

Ransburg

Figure 44: Needle Shaft Removal

3. Remove rear nut using the 79854-00 Special

Wrench.

Figure 45: Needle Shaft Removal

4. Attach a jam nut to the assembly and pull straight

out of the barrel.

Figure 46: 79853-00 Needle Shaft with 2k

Adjustable Packings

5. Clean cavity with non-metallic brush and

non-polar solvent.

6. Replace needle components as required. (See

"79853-00 Needle Shaft Parts List" in the "Parts

Identification" section for breakdown.)

Needle Shaft Rebuild

1. Prior to installing the needle shaft, coat the

exterior surfaces generously with dielectric grease.

2. Screw the needle electrode onto the front of

the needle shaft and hand tighten.

3. Fill the inner diameter of the packing tube with

dielectric grease - LSCH0009-00.

4. Insert the needle shaft, rear section first, into

the packing tube. Rotate the needle shaft while

moving back and forth inside the packng tube

until fully inserted.

NEEDLE SHAFT

REMOVAL /

REPLACEMENT

1. Remove barrel from the handle using previous

steps.

2. Remove cascade.

Figure 43: Cascade Removal

A

A

SECTION A-A

2

3

4

5

6

8

7

9

10

12

1

11

AH-08-03.6