Ransburg – Ransburg Vector Solo AA90 79698 User Manual
Page 40
Advertising
Vector Solo AA90 Applicators - Maintenance
Ransburg
36
AH-08-04.2
Figure 60: Fluid Fitting Removal
Power Module - Fluid Fitting
Removal
1. Remove swivel from the power module and
the power module from thehandle.
Figure 59: Power Module Removal
2. Remove two (2) screws using a 2.5mm Allen
wrench.
3. Remove the 1/4 module from the 3/4 module.
Pull the fluid fitting out.
Figure 61: Fluid Fitting Removal
Figure 62: Ground Clip Replacement
Fitting Replacement
1. Ensure the ground clip is properly installed.
Tabs must be touching the air and fluid fitting.
The ground clip must be properly in-
stalled such that it touches both the air and
fluid fitting.
W A R N I N G
!
C C W
Advertising