Vector Solo AA90 Applicators - Maintenance

Ransburg

36

AH-08-04.2

Figure 60: Fluid Fitting Removal

Power Module - Fluid Fitting

Removal

1. Remove swivel from the power module and

the power module from thehandle.

Figure 59: Power Module Removal

2. Remove two (2) screws using a 2.5mm Allen

wrench.

3. Remove the 1/4 module from the 3/4 module.

Pull the fluid fitting out.

Figure 61: Fluid Fitting Removal

Figure 62: Ground Clip Replacement

Fitting Replacement

1. Ensure the ground clip is properly installed.

Tabs must be touching the air and fluid fitting.

†

The ground clip must be properly in-

stalled such that it touches both the air and

fluid fitting.

W A R N I N G

!

C C W